DeDietrich GSHP 5 MR-E User Manual page 15

Geothermal heat pump
Hide thumbs Also See for GSHP 5 MR-E:
Table of Contents

Advertisement

Measurement
Unit
type
Heat output
kW
Tab.6
Performances for a glycol water/water system (0°C/-3°C and 40°C/45°C), in accordance with NF EN 14511–1
Measurement
Unit
type
Power supply
V
(~50 Hz)
Coefficient of
performance
(COP)
Absorbed electri­
kW
cal power
Heat output
kW
Tab.7
Performances for a water/water system (10°C/7°C and 30°C/35°C), in accordance with NF EN 14511–1
Caution
The tests to evaluate the performance of the heat pumps were run without a barrage exchanger. If that component
is used in the installation, performances are reduced and the specifications stated are no longer certified.
Caution
These performance tests have been carried out in order to comply with the requirements of the standard. Always
use a barrage exchanger (water/water) to protect the exchanger.
Measurement
Unit
type
Power supply
V
(~50 Hz)
Coefficient of
performance
(COP)
Absorbed electri­
kW
cal power
Application flow
3
m
/h
rate
Heat output
kW
Tab.8
Performances for a water/water system (10°C/7°C and 40°C/45°C), in accordance with NF EN 14511–1
Caution
The tests to evaluate the performance of the heat pumps were run without a barrage exchanger. If that component
is used in the installation, performances are reduced and the specifications stated are no longer certified.
Caution
These performance tests have been carried out in order to comply with the requirements of the standard. Always
use a barrage exchanger (water/water) to protect the exchanger.
Measurement
Unit
type
Power supply
V
(~50 Hz)
7636860 - v04 - 18012017
GSHP 5
GSHP 5
GSHP 9
MR-E
TR-E
MR-E
5.70
5.70
9.88
GSHP 5
GSHP 5
GSHP 9
MR-E
TR-E
MR-E
230
400
230
single
three-
single
phase
phase
phase
3.31
3.31
3.43
1.63
1.63
2.74
5.39
5.39
9.41
GSHP 5
GSHP 5
GSHP 9
MR-E
TR-E
MR-E
230
400
230
single
three-
single
phase
phase
phase
5.64
5.64
5.52
1.31
1.31
2.34
1.28
1.28
2.23
7.42
7.42
12.95
GSHP 5
GSHP 5
GSHP 9
MR-E
TR-E
MR-E
230
400
230
single
three-
single
phase
phase
phase
GSHP 9
GSHP
GSHP
TR-E
12 MR-E
12 TR-E
9.88
12.66
12.66
GSHP 9
GSHP
GSHP
TR-E
12 MR-E
12 TR-E
400
230
400
three-
single
three-
phase
phase
phase
3.43
3.42
3.42
2.74
3.57
3.57
9.41
12.21
12.21
GSHP 9
GSHP
GSHP
TR-E
12 MR-E
12 TR-E
400
230
400
three-
single
three-
phase
phase
phase
5.52
5.30
5.30
2.34
3.13
3.13
2.23
2.86
2.86
12.95
16.58
16.58
GSHP 9
GSHP
GSHP
TR-E
12 MR-E
12 TR-E
400
230
400
three-
single
three-
phase
phase
phase
3 Technical specifications
GSHP
GSHP
GSHP
15 TR-E
19 TR
27 TR
17.09
20.40
27.99
GSHP
GSHP
GSHP
15 TR-E
19 TR
27 TR
400
400
400
three-
three-
three-
phase
phase
phase
3.53
3.43
3.28
4.63
5.84
8.17
16.35
20.05
26.82
GSHP 15
GSHP
GSHP
TR-E
19 TR
27 TR
400
400
400
three-
three-
three-
phase
phase
phase
5.38
5.14
4.71
4.14
5.47
7.49
3.84
4.85
6.08
22.27
28.11
35.25
GSHP
GSHP
GSHP
15 TR-E
19 TR
27 TR
400
400
400
three-
three-
three-
phase
phase
phase
GSHP
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents