3
Technical specifications
3.1
Homologations
3.2
Technical data
Tab.3
Conditions of use
Limit operating temperatures in
heating mode
Limit operating temperatures in
cooling mode
Tab.4
Heating mode: outside air temperature +7°C, water temperature at the outlet +35°C. Performances in accordance with
EN 14511-2.
Measure
Unit
ment type
Heat out
kW
put
Coefficient
of Per
formance
(COP)
Absorbed
kWe
electrical
power
7623755 - v05 - 27042017
Water (°C)
For all models: +18 / +60
Except for AWHP 4.5 MR: +18 / +55
+7 / +25
AWHP 4
AWHP 4.5
AWHP 6
MR
MR
MR-2
AWHP 6
MR-3
3.94
4.6
5.79
4.53
5.11
4.05
0.87
0.90
1.43
3.1.1
Directives
This product complies with the requirements of the following European Di
rectives and Standards:
Pressure Equipment Directive 97/23/EC, Article 3, paragraph 3
Low Voltage Directive 2014/35/EU
Generic standard: EN 60335-1
Relevant standards: EN 60335-2-21, EN 60335-2-40
Electromagnetic Compatibility Directive 2014/30/EU
Generic standards: EN 61000-6-3, EN 61000-6-1
Relevant Standard: EN 55014
This product conforms to the requirements of European Directive
2009/125/EC on the ecodesign of energy-related products.
In addition to the legal requirements and guidelines, the supplementary
guidelines in this manual must also be followed.
Supplements or subsequent regulations and guidelines that are valid at
the time of installation shall apply to all regulations and guidelines speci
fied in this manual.
3.2.1
Heat pump
Maximum operating pressure: 0.3 MPa (3 bar)
AWHP 8
AWHP 11
MR-2
MR-2
7.9
11.39
4.34
4.65
1.82
2.45
3 Technical specifications
Outside air (°C)
For all models: -20 / +35
Except for: AWHP 4 MR, AWHP 4.5 MR,
AWHP 6 MR-2, AWHP 6 MR-3 : -15 / +35
+7 / +40
AWHP 11
AWHP 16
TR-2
MR-2
11.39
14.65
4.65
4.22
2.45
3.47
AWHP 16
TR-2
14.65
4.22
3.47
MIV-4
17