DeDietrich GSHP 5 MR-E User Manual page 30

Geothermal heat pump
Hide thumbs Also See for GSHP 5 MR-E:
Table of Contents

Advertisement

6 Settings
Parameters
COLD
MANUEL
Tab.16
Domestic Hot Water menu (
Parameters
AUTOMATIC
COMFORT 7/7
COMFORT ->
Tab.17
#MEASURES menu - User Level
Parameters
OUTSIDE TEMP.
ROOMTEMP.A
ROOMTEMP.B
ROOMTEMP.C
HP FLOW TEMP.
BACK TEMP HP
SOURCE T.IN
SOURCE T.OUT
PRESSURE
DHW TEMP.
S.TAN.T.SYS.BO
STO.TANK.T.AUX
TEMPERATURE DCW
SWIMMING P.T.B
SWIMMING P.T.C
OUTLET TEMP.B
OUTLET TEMP.C
TEMP.SYSTEM
TEMP.TANK AUX
30
GSHP
Description
COOLING mode is forced without taking into account the
outside temperature or the SUM/WIN parameter.
The appliance operates according to the set point settings.
All of the pumps operate.
Possibility of setting the set point by simply turning the but­
ton.
)
Description
Domestic hot water production is determined by the setting in the #TIME
PROGRAM menu.
Domestic hot water production is forced at all times: seven days a week.
Domestic hot water production is forced until the set time:
Certain parameters are displayed:
Description
Outside temperature
Room temperature on circuit A
Room temperature on circuit B
Room temperature on circuit C
Condenser flow temperature
Condenser return temperature
Intake temperature from the source
Flow temperature from the source
Water pressure in the system
Water temperature in the domestic hot water tank (top sensor)
Sensor temperature in the bottom of the storage tank
Sensor temperature in the top of the storage tank
Temperature in the domestic hot water tank (bottom sensor)
Water temperature of the swimming pool on circuit B
Water temperature of the swimming pool on circuit C
Water flow temperature in circuit B
Water flow temperature in circuit C
Water flow temperature in the system in the event of multiple sources
Water temperature in the second domestic hot water tank connected to the Aux­
iliary circuit
Domestic Hot Water menu - User Level
#MEASURES menu - User Level
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Factory setting
Customer setting
Factory setting
Current time + 1
hour
Current time + 1
hour
Unit
°C
°C
°C
°C
°C
°C
°C
°C
bar
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
7636860 - v04 - 18012017

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents