Relay output
Programmable relay output
Relay 01 and 02
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
(NC) (Resistive load)
Environment according to EN 60664-1
1) IEC 60947 parts 4 and 5.
Control card, 10V DC output
Terminal number
Output voltage
Max. load
All inputs, outputs, circuits, DC supplies and relay contacts are galvanically isolated from the supply voltage (PELV) and
other high-voltage terminals.
Surroundings
Enclosure
Enclosure kit available.
Vibration test
Max. relative humidity
Aggressive environment (IEC 60721-3-3), coated (standard) frame H1-H5
Aggressive environment (IEC 60721-3-3), non-coated frame H6-H10
Aggressive environment (IEC 60721-3-3), coated (optional) frame H6-H10
Test method according to IEC 60068-2-43 H2S (10 days)
Ambient temperature
Derating for high ambient temperature, see section on special conditions
Minimum ambient temperature during full-scale operation
Minimum ambient temperature at reduced performance, enclosure frame H1-H5
Minimum ambient temperature at reduced performance, enclosure frame H6-H10
Temperature during storage/transport
Maximum altitude above sea level without derating
Maximum altitude above sea level with derating
Derating for high altitude, see section on special conditions
Safety standards
EMC standards, Emission
EMC standards, Immunity
1-44
VLT HVAC Basic Drive Quick Guide
1)
on 01-02/04-05 (NO) (Resistive load)
1)
on 01-02/04-05 (NO) (Inductive load @ cosφ 0.4)
1)
on 01-02/04-05 (NO) (Resistive load)
1)
on 01-02/04-05 (NO) (Inductive load)
1)
on 01-03/04-06 (NC) (Resistive load)
1)
on 01-03/04-06 (NC) (Inductive load @ cosφ 0.4)
1)
on 01-03/04-06
Min. terminal load on 01-03 (NC), 01-02 (NO) 24 V DC 10 mA, 24 V AC 20 mA
See max. output current at 104°/122° F [40°/50°C] in the tables line power supply
EN 61800-3, EN 61000-3-12, EN 61000-6-1/2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN
MG18A322 - VLT
01-03 (NC), 01-02 (NO), 04-06 (NC), 04-05 (NO)
Overvoltage category III/pollution degree 2
5–95% (IEC 60721-3-3; Class 3K3 (non-condensing) during operation
EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
®
is a registered Danfoss trademark
250 V AC, 3A
250 V AC, 0.2 A
30 V DC, 2A
24 V DC, 0.1A
250 V AC, 3A
250 V AC, 0.2 A
30 V DC, 2A
10.5 V ±0.5 V
25 mA
IP21, TYPE 1
Class 3C3
Class 3C2
Class 3C3
32° F [0°C]
-4° F [-20°C]
14° F [-10°C]
-22°–+149°/158° F [-30–+65°/70°C]
3,280 ft [1,000 m]
9,842 ft [3,000 m]
EN/IEC 61800-5-1, UL 508C
61000-4-5, EN 61000-4-6
2
50
IP20
1.0 g