Enabling The Automated Attendant - NEC Univerge UM8000 Installation Manual

Hide thumbs Also See for Univerge UM8000:
Table of Contents

Advertisement

Issue No. 1.0
2.5
8 - 4
4.
Assign the phantom extension number to the UCD pilot (master) number.
Command Code:
First Data:
Second Data:
5.
Assign all UCD numbers to UCD group number 00.
Command Code:
First Data:
Second Data:
NOTE
Repeat this command for each voice messaging extension number and
for the UCD pilot (master) number.
6.
Make busy the UCD pilot extension number.
Command Code:
First Data:
Second Data:
7.
Assign the UCD pilot (master) number to the tenant number.
Command Code:
First Data:
Second Data:

Enabling the Automated Attendant

To use the voice messaging system as an automated attendant, program the
phone system to send external calls to the UCD pilot (master) extension.
171
xxx
Where <xxx> is the UCD pilot
extension number.
1
172
xxx
Where <xxx> is the extension
number.
000
E50
xxx
Where <xxx> is the UCD pilot
extension number.
0
5115
000
xxx
Where <xxx> is the UCD pilot
extension number.
Setting Up Integration (SV8300)