Ring/Network Coupling
Note: Configure the coupling port and the redundancy ring ports on different
ports.
Activate the function in the "Operation" frame
Now connect the redundant line and the control line.
The displays in the "Select port" frame mean:
– "Port mode": The port is either active or in stand-by mode.
– "Port state": The port is either active, in stand-by mode or not
connected.
– "IP Address": The IP address of the partner, if the partner is already
operating in the network.
The displays in the "Information" frame mean:
– "Redundancy guaranteed": If the main line no longer functions, the
redundant line takes over the function of the main line.
– "Configuration failure": The function is incomplete or incorrectly
configured.
To avoid continuous loops, the Switch sets the port state of the coupling
port to "off" if you:
– switch off the operation setting or
– change the configuration
while the connections are in operation at these ports.
Note: The following settings are required for the coupling ports (you
select the Basic Settings:Port Configuration dialog):
– Port: on
– Automatic configuration (autonegotiation):
on for twisted-pair connections
– Manual configuration: 100 Mbit/s FDX, 1 Gbit/s FDX, or 10 Gbit/s
FDX, according to the port's capabilities
for glass fiber connections
Note: If VLANs are configured, set the coupling and partner coupling
ports' VLAN configuration as follows:
– in the dialog Switching:VLAN:Port Port VLAN ID 1 and „Ingress
Filtering" deactivated
– in the dialog Switching:VLAN:Static VLAN-Membership U
(Untagged)
Redundancy mode
84
5.2 Preparing a Ring/Network
(see figure 38)
UM RedundConfig L2P
Release 8.0 05/2013
Coupling