Ring Redundancy
Note: Configure all the devices of the Fast HIPER-Ring individually. Before
you connect the redundant line, you must complete the configuration of all
the devices of the Fast HIPER-Ring. You thus avoid loops during the
configuration phase.
Set up the network to meet your demands.
Configure all ports so that the transmission speed and the duplex settings
of the lines correspond to the following table:
Bit rate
Autonegotiation
(automatic configuration)
Port
Duplex
Table 5:
Port settings for ring ports
Select the Redundancy:Ring Redundancy dialog.
Under "Version", select Fast HIPER-Ring.
Define the desired ring ports 1 and 2 by making the corresponding
entries in the module and port fields. If it is not possible to enter a
module, then there is only one module in the device that is taken
over as a default.
Display in "Operation" field:
forwarding: this port is switched on and has a link.
blocked: this port is blocked and has a link
disabled: this port is disabled
not-connected: this port has no link
UM RedundConfig L2P
Release 8.0 05/2013
3.3 Example of a Fast HIPER-Ring
100 Mbit/s
off
on
Full
1000 Mbit/s
on
on
–
41