Ring/Network Coupling
Figure 33: Two-Switch coupling: Selecting the redundancy mode
With the "Redundant Ring/Network Coupling" setting, either the
main line or the redundant line is active. The lines are never both active
at the same time.
With the "Extended Redundancy" setting, the main line and the
redundant line are simultaneously active if the connection line between
the devices in the connected (i.e. remote) network fails
During the reconfiguration period, package duplications may occur.
Therefore, only select this setting if your application detects package
duplications.
Figure 34: Extended redundancy
Coupling mode
UM RedundConfig L2P
Release 8.0 05/2013
5.2 Preparing a Ring/Network
(see figure
Coupling
27).