Ring/Network Coupling
Application
Disadvantage
Advantage
Table 7:
Selection criteria for the configuration types for redundant coupling
Note: Choose a configuration based on topological conditions and the level
of availability you require
UM RedundConfig L2P
Release 8.0 05/2013
One-Switch coupling Two-Switch coupling Two-Switch coupling
The 2 devices are in
impractical topological
positions.
Therefore, putting a
line between them
would involve a lot of
effort for two-Switch
coupling.
If the Switch
configured for the
redundant coupling
becomes inoperable,
no connection remains
between the networks.
Less effort involved in
connecting the 2
devices to the network
(compared with two-
Switch coupling).
(see table
5.1 Variants of the ring/network
The 2 devices are in
practical topological
positions.
Installing a control line
would involve a lot of
effort.
More effort for
connecting the 2
devices to the network
(compared with one-
Switch coupling).
If one of the devices
configured for the
redundant coupling
becomes inoperable,
the coupled networks
are still connected.
7).
coupling
with control line
The 2 devices are in
practical topological
positions.
Installing a control line
would not involve
much effort.
More effort for
connecting the two
devices to the network
(compared with one-
Switch and two-Switch
coupling).
If one of the devices
configured for the
redundant coupling
becomes inoperable,
the coupled networks
are still connected.