Hirschmann RS20 User Manual page 83

Redundancy configuration industrial ethernet (gigabit-)switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Ring/Network Coupling
Note: The following settings are required for the coupling ports (you
select the Basic Settings:Port Configurationdialog):
See table 3 on page 30.
Note: If VLANs are configured, set the coupling and partner coupling
ports' VLAN configuration as follows:
– in the dialog Switching:VLAN:Port Port VLAN ID 1 and „Ingress
Filtering" deactivated
– in the dialog Switching:VLAN:Static VLAN-Membership U
(Untagged)
 Select "Two-Switch coupling with control line" by means of the dialog
button with the same graphic as below
3
2
STAND-BY
Figure 39: Two-Switch coupling with control line
1: Coupling port
2: Partner coupling port
3: Control line
The following settings apply to the Switch displayed in blue in the
selected graphic.
 Select the coupling port
With "Coupling port" you specify at which port you are connecting
the network segments:
You will find the port assignment for the redundant coupling
in
table
12.
 For a device with DIP switches, you switch the STAND-BY switch to
ON or deactivate the DIP switches. You connect the redundant line
to the coupling port.
 Select the control port
With "Control port" you specify at which port you are connecting the
control line.
UM RedundConfig L2P
Release 8.0 05/2013
1
ON
(see figure
(see figure 38)
5.2 Preparing a Ring/Network
(see figure
39).
38).
Coupling
83