Multiple Rings
Figure 20: Sub-Ring – New Entry dialog
Enter the value "1" as the ring ID of this Sub-Ring.
In the Module.Port field, enter the ID of the port (in the form X.X) that
connects the device to the Sub-Ring (in the example, 1.9). For the
connection port, you can use all the available ports that you have not
already configured as ring ports of the basis ring.
You have the option of entering a name for the Sub-Ring (in the
example, "Test").
Select the Sub-Ring Manager mode (SRM mode). You thus specify
which connection between the primary ring and the Sub-Ring
becomes the redundant line.
The options for the connection are:
Both Sub-Ring Managers have the same setting (default manager): - the device
with the higher MAC address manages the redundant line.
In the SRM Mode field, a device is selected to be the redundant manager: -
this device manages the redundancy line as long as you have configured the
other Sub-Ring Manager as a manager, otherwise the higher MAC address
applies.
Configure Sub-Ring Manager 1 as the "manager" and Sub-Ring
Manager 2 as the manager of the redundant line with "redundant
manager", in accordance with the overview drawing for this
example.
54
4.1 Sub-Ring
UM RedundConfig L2P
Release 8.0 05/2013