Tp Sensor Reset Procedure - Honda PCX150 2013 Service Manual

Table of Contents

Advertisement

• Make sure that no OTC is stored in the ECM. If a
OTC is stored, follow the TP sensor reset procedure
below.
Remove the following:
-
Battery maintenance lid (page 20-7)
-
Right side cover (page 2-8)
1. Turn the ignition switch OFF.
2. Remove the dummy connector [1] from the DLC [2].
3. Connect the special tool to the DLC.
TOOL:
[3] SCS connector
070PZ-ZY30100
4. Disconnect the ECT sensor 2P (Black) connector
[1 ].
Short the ECT sensor terminals with jumper wire [2].
CONNECTION: Pink/white - Green/orange
5.
Turn the ignition switch ON and engine stop switch
"O", then disconnect the jumper wire from the ECT
sensor 2P (Black) connector within 10 seconds
while the MIL is blinking (reset receiving pattern).
6.
Check if the MIL blinks.
After disconnection of the jumper wire, the MIL
should start blinking. (successful pattern)
If the jumper wire is connected for more than
10 seconds, the MIL will stay· ON (unsuccessful
pattern). Try again from the step
4.
ijf
ij ____
w_i_th_in_1_0_s_e_c. _ _ _ _ ..,..
0.1 sec.
... 4'
.l[§Jt
MIL ON
A,,_,.,..,
__ ...1 ___
1 _ _ _ _ _ 1
1
1.2 sec .
I
MIL OFF ______ - . - - - - '
IGNITION
SWITCH
RESET RECEIVING PATTERN
ON - -
Install the removed parts in the reverse order of
removal.
Check the engine idle speed (page 3-13).
cIJ
1
0.3 sec.
~ltsec
~
I
SUCCESSFUL PATTERN
SYSTEM
TP SENSOR IS
RESET
SUCCESSFULLY.