Troubleshooting - Ranger Laser-Spot LS43B Installation And Operation Manual

Table of Contents

Advertisement

Troubleshooting

Perform the following checks if you are experiencing balancing problems:
Confirm the location and alignment of the alignment marks on the Shaft Assembly and Shaft
Housing (see
Make sure the Balancer is anchored in place (see
information).
Perform a Weight Location Verification Test (see
information).
Perform the calibration with a steel Wheel of the most commonly used size.
Note:
Make sure the calibration weight used is a 100 gram or 3.5 ounce weight and that is mounted
correctly during the calibration procedure.
Issues
Issue
Nothing on the Display Panel.
No beep when using the Inner Arm
or the Outer Arm.
The Outer Arm is not producing
correct values on a consistent basis.
The Inner Arm is not producing
correct values on a consistent basis.
The Balancer is not producing good
balances on a consistent basis.
If you continue to have problems with your Wheel Balancer, visit
call BendPak Ranger at (805) 933-9970.
LS43B Laser-Spot™ Wheel Balancer
Installing the Shaft
It is a good practice to keep a known good Wheel of the most commonly used size to
use as a calibration / reference tire to assist in troubleshooting.
for more information).
Anchoring the Balancer
Weight Location Verification Test
Action to Take
Make sure the unit is turned on and getting power.
Make sure the unit is turned on and getting power. Make sure
the Outer Arm was correctly installed.
Calibrate the Outer Arm. Refer to
Arm
for more information.
Calibrate the Inner Arm. Refer to
Arm
for more information.
Perform a Weight Location Verification Test. Refer to
Location Verification Test
40
for more
Calibrating the Outer
Calibrating the Inner
for more information.
www.bendpak.com/support/
P/N 5900086 — Rev. A1 — 12/212018
for more
Weight
or

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents