Setting Of Ncu Parameters - Canon MF720 Series Service Manual

Hide thumbs Also See for MF720 Series:
Table of Contents

Advertisement

No.
07
Spare
08
STORED_DIAL_MODE wait timer
09
Not in use
10
T.30 T0 timer
11
T.30 T1 timer (for incoming transmission)
12
Maximum incoming lines
13
T.30 EOL timer
14
Not in use
15
Threshold between hokking nad on-hook
16
Lead time to the first response when switching between FAX and TEL
17
Duration to activate pseudo-RBT cadence
18
Duration to deactivate pseudo-RBT cadence (short)
19
Duration to deactivate pseudo-RBT cadence (long)
20
Duration to activate pseudo-ring cadence
21
Duration to deactivate OFF Hook cadence (short)
22
Duration to deactivate OFF Hook cadence (long)
23 to 24
Not in use
25
CNG monitor duration while the answering device is activated
26 to 28
Not in use
29
Off-hook PCB duty settings(For NAC, setting can be made with SPL71100
in special management mode.)
30 to 48
Not in use
49
NSX MODEL ID
50
Not in use
51
Threshold to detect hook
52
Not in use
53
Set DTMF calling counts when receiving FAX remotely
54
Set Busy Tone outgoing duration when using handset
55 to 80
Not in use

Setting of NCU Parameters

■ TONE/PULSE
Operation Method
1. Setting of Tone Parameters
Operate as follows, and change to the parameter setting mode.
1. While "#NCU" is displayed, press "OK" key
2. Press "#TONE" key
3. Press "OK" key
2. Setting of Pulse Parameters
Operate as follows, and change to the pulse setting mode.
1. While "#NCU" is displayed, press "OK" key
2. Press "#PULSE" key
3. press "OK" key
Item
TONE
PULSE
PULSE FORM
PULSE NUM
Numeric parameter setting mode
Parameter
Function
01;
Tone signal sending time (PSTN)
02;
Minimum pause time (PSTN)
Pulse digit format
01;
Not in use
02;
Not in use
03;
Pulse dial make ratio
304
8. Service Mode
Allowable setting range
0 to 65 sec
55 sec principally
0 to 9999 (France: 3500, Others: 3000)
0 to 65535 (line)0: without limitation
500 to 3000 (set to 55 sec by default)
0 to 999
0 to 9
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 7
0 to 999
20 (*10ms)
0 to 4095
10 to 9999
10 to 9999 (default 25)
Setting range
10 to 9999 (msec)
10 to 9999 (msec)
0 to DP ( N )
1 to DP ( N+1 )
2 to DP ( 10-N )
10 to 90 (%)