1. Press Yes key.
2. Turn OFF / ON the main power switch.
Clearing of Card Reader connection info
To clear the information on connection of the Copy Card Reader-F1.
The data related to the card ID (department) is cleared, and the ID and password of the system adminis-
trator are initialized.
When removing the Card Reader-F1
When removing the Card Reader-F1
1. Disable the department ID management.
2. Press Yes key.
3. In COPIER > FUNCTION > CLEAR > CARD, clear the information on connection of the Copy Card
Reader-F1.
4. Execute COPIER > FUNCTION > CLEAR > E719-CLR.
5. Turn OFF the main power.
6. Remove the Card Reader-F1.
7. Turn ON the main power.
• Execute this item after disabling the department ID management via LUI or RUI
• Then, clear the information on connection of the Copy Card Reader-F1 and execute E719-CLR (clear
E71 )
COPIER > FUNCTION > CLEAR > E719-CLR
Clearing of E719 error
To clear E719 error (communication error with the Card Reader).
When removing the Card Reader-F1
When removing the Card Reader-F1
1. Disable the department ID management.
2. Press Yes key.
3. In COPIER > FUNCTION > CLEAR > CARD, clear the information on connection of the Copy Card
Reader-F1.
4. Execute COPIER > FUNCTION > CLEAR > E719-CLR.
5. Turn OFF the main power.
6. Remove the Card Reader-F1.
7. Turn ON the main power.
COPIER > FUNCTION > CLEAR > CARD
Clearing of setting information
Clear/initialize the following setting information according to the location set in COPIER > OPTION > BODY
> LOCALE, SIZE-LC:
• User mode setting values
• Service mode setting values (excluding service counter)
• ID and password of the system administrator
• Communication management / printing / jam / error history
• E719-CLR (counter meter-installed models only) The following is not initialized:
• Service counter
• Factory adjustment values of the Reader / ADF
At installation
1. Press Yes key.
2. Turn OFF / ON the main power switch.
COPIER > OPTION > BODY > LOCALE, SIZE-LC
Initialization of Embedded-RDS setting value
To initialize the Embedded-RDS setting values.
ON / OFF of Embedded-RDS, UGW (remote monitoring service system) port number, and communication
error log set in service mode are initialized.
When upgrading the version of Bootable in the Embedded-RDS environment
Press Yes key.
Use of the SRAM in Embedded-RDS differs depending on the Bootable version.
Therefore, unless initialization is executed at the time of version upgrade, data inconsistency occurs.
Description