■ INSTALL
Item
STRD-POS
Title
Details
Use case
Adj/set/operate method
Caution
Related service mode
E-RDS
Title
Details
Use case
Adj/set/operate method
Caution
Display/adj/set range
Default value
Related service mode
Supplement/memo
RGW-PORT
COPIER > FUNCTION > SPLMAN
1. Enter the setting value, and then press Apply key.
2. Turn OFF/ON the main power switch.
0 to 1
0
Switching to enable / disable PC-less update
To switch whether to enable the PC-less update function.
1. Enter the setting value, and then press Apply key.
2. Turn OFF/ON the main power switch.
0 to 1
0 : Disabled
1 : Enabled (default)
1
Switching to display the connection destination URL setting of GoogleCloudPrint on the remote UI
To display the connection destination URL setting of GoogleCloudPrint on the remote UI.
1. Enter the setting value, and then press Apply key.
2. Turn OFF/ON the main power switch.
0 to 1
0: Do not display
1: Display
0
COPIER > FUNCTION > INSTALL
Scan position auto adj in ADF mode
To adjust the ADF scanning position automatically.
At ADF installation/uninstallation
1. Set a paper for stream reading position adjustment, and then close the ADF.
2. Select the item, and then press Yes key. The operation automatically stops after the adjustment.
3. Write the value displayed by COPIER > ADJUST > ADJ-XY > STRD-POS in the service label.
Write the adjusted value in the service label.
COPIER > ADJUST > ADJ-XY > STRD-POS
ON / OFF of Embedded-RDS
To set ON / OFF of Embedded-RDS function.
When using Embedded-RDS
1. Select the item, and then press Yes key.
2. Turn OFF / ON the main power switch.
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
0 to 1 0 : OFF 1 : ON
0
COPIER > FUNCTION > INSTALL >
COPIER > FUNCTION > INSTALL > RGW-PORT
COPIER > FUNCTION > INSTALL > COM-TEST
COPIER > FUNCTION > INSTALL > COM-RSLT
COPIER > FUNCTION > INSTALL > COM-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and con-
sumables to UGW via SOAP protocol
UGW (Universal Gate Way): Remote monitoring service system
Description
Description