Image Formation System Disassembly/Assembly Procedure; Removing The Itb Unit - Canon MF720 Series Service Manual

Hide thumbs Also See for MF720 Series:
Table of Contents

Advertisement

Image Formation System
Disassembly/Assembly
Procedure

Removing the ITB Unit

■ Preparation
1. Removing the Cartridge Tray.(Refer to
the Cartridge Tray" on page
■ Procedure
CAUTION:
Be sure not to touch the surface of the ITB and the
Secondary Transfer Roller when disassembling/
assembling.
"Removing
127)
191
1. Pull out the Patch Density/Registration Sensor Unit
[1] toward the front.
• 2 Screws [2]
• 2 Bosses [3]
• 2 Protrusions [4]
[2]
2x
When it is difficult to pull out the Patch Density/
Registration Sensor Unit toward the front and there is a
risk of contact with the ITB, refer to "Removing the Patch
Density and Registration Sensor Unit" so that the Patch
Density/Registration Sensor Unit [1] can be further
pulled out. (Refer to
"Removing the Patch Density and
Registration Sensor unit" on page
2. Disconnect the connector [1].
1x
4. Disassembly/Assembly
[2]
[1]
[3]
[3]
[4]
[1]
193)
[1]

Advertisement