List Of Num; Setting Of Ncu Parameters; Tone/Pulse - Canon L100 Service Manual

Hide thumbs Also See for L100:
Table of Contents

Advertisement

List of NUM

Numeric parameter setting mode
No.
Parameter
001
Not in use
002
RTN transmission criteria X
003
RTN transmission criteria n
004
RTN transmission criteria m
005
NCC pause (before ID code)
006
NCC pause (after ID code)
007 - 009 Not in use
010
T.30 T0 timer
011
T.30 T1 timer (for incoming transmission)
012
Maximum incoming lines
013
T.30 EOL timer
014
Not in use
015
Threshold between hokking nad on-hook
016
Lead time to the first response when switching between
FAX and TEL
017
Duration to activate pseudo-RBT cadence
018
Duration to deactivate pseudo-RBT cadence (short)
019
Duration to deactivate pseudo-RBT cadence (long)
020
Duration to activate pseudo-ring cadence
021
Duration to deactivate OFF Hook cadence (short)
022
Duration to deactivate OFF Hook cadence (long)
023
CNG detection level when switching between FAX and
TEL
024
Pseudo-RBT outgoing level when switching between
FAX and TEL
025
CNG monitor duration while the answering device is
activated
026
No signal detection level while the answering device is
activated
027
Duration to detect preamble of V21 low-speed flag
028 - 050 Not in use
051
Threshold to detect hook
052
Not in use
053
Set DTMF calling counts when receiving FAX remotely 10 to 9999 (default 25)
054
Set Busy Tone outgoing duration when using handset
055 - 080 Not in use
8
Service Mode > FAX > Setting of NCU Parameters > TONE/PULSE
Allowable setting range
1 to 99 %
2 to 99 times
1 to 99 lines
1 to 60 sec
1 to 60 sec
55 sec principally
0 to 9999
(France: 3500, Others: 3000)
0 to 65535 (line)
0: without limitation
500 to 3000
(set to 55 sec by default)
0 to 999
0 to 9
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 7
10 to 20 (100 V)
0 to 20 (120, 230 V)
0 to 999
0 to 7
20 (*10 ms)
10 to 9999
T-8-22
8
Service Mode > FAX > Setting of NCU Parameters > TONE/PULSE

Setting of NCU Parameters

■ TONE/PULSE

Operation Method
1) Setting of Tone Parameters
While "#NCU" is displayed, press "OK" key -> Select "#TONE" and press "OK" key so that
it becomes tone parameter setting mode.
2) Setting of Pulse Parameters
While "#NCU" is displayed, press "OK" key -> Select "#PULSE" and press "OK" key so that
it becomes pulse parameter setting mode.
Item
TONE
001;
Tone signal sending time (PSTN)
002;
Minimum pause time (PSTN)
PULSE
FORM
Pulse digit format
001;
Pulse dial speed (10 pps)
002;
Pulse dial speed (20 pps)
003;
Pulse dial make ratio
004;
Minimum pause time
DIALTONE
● Bit Switch
Bit No.
Function
Bit 0
Frequency detection method
Modem
Bit 1
Not in use
Bit 2
Signal frequency
Changed
Bit 3
Not in use
Bit 4
Judgment of intermittent signal start from valid ON signal start from either valid ON
Bit 5
Not in use
Bit 6
Signal form
Continuous
Bit 7
Signal detection
Detected
● Numeric value parameter
Parameter No.
Function
001;
T0 timer
002;
T1 timer
003;
T2 timer
004;
T3 timer
Function
Setting range
10 to 9999 (msec)
10 to 9999 (msec)
0 -> DP (N)
1 -> DP (N+1)
2 -> DP (10-N)
5 to 300 (x0.1 pps)
5 to 300 (x0.1 pps)
10 to 90 (%)
10 to 9999 (msec)
1
0
Tonal counter
-
-
Not changed
-
-
signal or OFF signal
-
-
Intermittent
Not detected
T-8-24
Setting range
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
8-11
T-8-23