Chapter 7
7.7.3
Wiring Portion Under Control Circuit
・[ ] indicates the factory default setting.
Alarm relay output
terminal
AL2 AL1
AL0
AL:[AL]
Output terminals
15
14
13
[OL]
[IRDY]
[FA2]
B
A
[USP]
[EXT]
・When connecting contacts to control
circuit terminals, use a relay that does
Mal-
not generate contact failure even at
functioning
weak current or voltage emitted from
cross-bar twin contacts.
Do
・When connecting a relay with output
terminals, connect a diode for
Failure
absorbing surge in parallel with the
coil. Otherwise, internal elements may
burn.
Do
(See the chapter for output terminals)
Relay output
terminal
16A 16C
16:
[ZS]
Control circuit terminal area
12
11
CM2
[FA1]
[RUN]
Input terminals
9
8
7
COM
[FW]
[RV]
[CF2]
Wire Connection and Optional Devices
6
5
4
COM
[CF1]
[2CH]
[FRS]
Logic of input terminals
Using SW6, switch the sink/source
logic.
7-28
3
1
2
COM
[JG]
[RS]
[SCHG]