Chapter 7
400V class
・At inverter ND rating setting
P1 model
Applicable
P1-*******
motor
(P1-****)
(kW)
P1-00041-H(P1-007H)
0.75
P1-00054-H(P1-015H)
1.5
P1-00083-H(P1-022H)
2.2
P1-00126-H(P1-037H)
3.7
P1-00175-H(P1-055H)
5.5
P1-00250-H(P1-075H)
7.5
P1-00310-H(P1-110H)
11
P1-00400-H(P1-150H)
15
P1-00470-H(P1-185H)
18.5
P1-00620-H(P1-220H)
22
P1-00770-H(P1-300H)
30
P1-00930-H(P1-370H)
37
P1-01160-H(P1-450H)
45
P1-01470-H(P1-550H)
55
P1-01760-H(P1-750H)
75
P1-02130-H(P1-900H)
90
P1-02520-H(P1-1100H)
110
P1-03160-H(P1-1320H)
132
・At inverter LD/VLD rating setting
P1 model
Applicable
P1-*******
motor
(P1-****)
(kW)
P1-00041-H(P1-007H)
1.5
P1-00054-H(P1-015H)
2.2
P1-00083-H(P1-022H)
3.7
P1-00126-H(P1-037H)
5.5
P1-00175-H(P1-055H)
7.5
P1-00250-H(P1-075H)
11
P1-00310-H(P1-110H)
15
P1-00400-H(P1-150H)
18.5
P1-00470-H(P1-185H)
22
P1-00620-H(P1-220H)
30
P1-00770-H(P1-300H)
37
P1-00930-H(P1-370H)
45
P1-01160-H(P1-450H)
55
P1-01470-H(P1-550H)
75
P1-01760-H(P1-750H)
90
P1-02130-H(P1-900H)
110
P1-02520-H(P1-1100H)
132
P1-03160-H(P1-1320H)
160
* If export to the U.S. or Canada or compliance with UL/cUL
standards is required, you need to use wires and breakers
specified in the UL/cUL standards. For details, see "1.7
Compliance with UL Standards".
* The models described in the table are examples of selection.
When using the device, choose a model that has appropriate
breaking capacity and sensitive current by taking short circuit
current and relevant laws and regulations into consideration
based on the rated current shown in the table.
* The applicable motor capacity is a selection example when
Hitachi IE3 4-pole motor model of 60HZ 400VAC (400V class) is
used.
* For the power line diameter, see the "Power line" column in the
table shown in "7.5.4 Recommended Wire Diameter, Wiring
Tools, and Crimping Terminals".
Without power factor improvement reactor (DCL or ACL) With power factor improvement reactor (DCL or ACL)
Earth-leakage breaker (ELB) Magnetic contactor (MC) Earth-leakage breaker (ELB) Magnetic contactor (MC)
Example of
Rated current
model
EX50C
5
EX50C
10
EX50C
10
EXK50-C
15
EXK50-C
20
EXK50-C
30
EXK50-C
40
EXK50-C
50
EXK100-C
75
EXK100-C
75
EXK100-C
100
RXK125-S
125
EXK225
150
EXK225
200
H100C
RXK250-S
250
H150C
EX400
300
H200C
EX400
400
H200C
EX600B
500
H250C
Without power factor improvement reactor (DCL or ACL) With power factor improvement reactor (DCL or ACL)
Earth-leakage breaker (ELB) Magnetic contactor (MC) Earth-leakage breaker (ELB) Magnetic contactor (MC)
Example of
Rated current
model
EX50C
10
EX50C
10
EXK50-C
15
EXK50-C
20
EXK50-C
30
EXK50-C
40
EXK50-C
50
EXK100-C
75
EXK100-C
75
EXK100-C
100
RXK125-S
125
EXK225
150
EXK225
200
H100C
EX400
250
H150C
EX400
300
H200C
EX400
400
H200C
EX600B
500
H250C
EX600B
600
H400C
Wire Connection and Optional Devices
Applicable instrument (input voltage 400-440V)
Example of
AC-1
AC-3
model
HS8
HS8
EX50C
HS8
HS8
EX50C
HS8
HS8
EX50C
HS8
HS10
EX50C
HS8
HS20
EXK50-C
HS8
HS25
EXK50-C
HS20
HS35
EXK50-C
HS25
HS50
EXK50-C
HS35
HS50
EXK50-C
HS50
H65C
EXK60-C
HS50
H80C
EXK100-C
H80C
H100C
EXK100-C
H80C
H125C
RXK125-S
H125C
EXK225
H200C
EXK225
H250C
EXK225
H300C
EX400
H300C
EX400
Applicable instrument (input voltage 400-440V)
Example of
AC-1
AC-3
model
HS8
HS8
EX50C
HS8
HS8
EX50C
HS8
HS10
EX50C
HS8
HS20
EXK50-C
HS8
HS25
EXK50-C
HS20
HS35
EXK50-C
HS25
HS50
EXK50-C
HS35
HS50
EXK50-C
HS50
H65C
EXK60-C
HS50
H80C
EXK100-C
H80C
H100C
EXK100-C
H80C
H125C
RXK125-S
H125C
EXK225
H200C
EXK225
H250C
EXK225
H300C
EX400
H300C
EX400
H400C
EX400
* The electric durability ensured when the magnetic contactor is
used in AC-1 class is 500,000 times, while emergency stop
during motor operation is 25 times.
* If there is emergency stop during motor drive or commercial
operation is performed, choose the magnetic contactor on the
motor side in AC-3 class against the rated current of motor.
* If the rated capacity of inverter is larger than the motor capacity,
choose instruments based on the inverter model.
7-12
Rated current
AC-1
5
HS8
5
HS8
10
HS8
10
HS8
15
HS8
20
HS20
30
HS25
40
HS35
50
HS50
60
HS50
75
H80C
100
H80C
H100C
125
H100C
H125C
150
H150C
H125C
200
H200C
H200C
225
H200C
H250C
300
H250C
H300C
350
H400C
H400C
Rated current
AC-1
5
HS8
10
HS8
10
HS8
15
HS8
20
HS8
30
HS8
40
HS20
50
HS20
60
HS35
75
HS50
100
HS50
125
H65C
150
H80C
H100C
200
H100C
H125C
225
H125C
H150C
300
H150C
H250C
350
H200C
H250C
400
H250C
H300C
AC-3
HS8
HS8
HS8
HS10
HS20
HS25
HS35
HS50
HS50
H65C
H80C
AC-3
HS8
HS8
HS8
HS20
HS20
HS25
HS35
HS35
HS50
H65C
H65C
H80C