Chapter 12
12.24.6
Checking the number of input
pulses
• I want to use the pulse string input to count the
pulses for outputting.
• For the pulse counting function, the terminal input
monitoring mode and the phase coefficient
monitoring mode are available.
• When the "Selection of targets for pulse string input
detection [CA-90]" ranges from 00 to 02, the
terminal input monitoring mode becomes valid.
When [CA-90] is set to "03 (pulse count)," the
phase coefficient monitoring mode becomes valid.
• You can monitor the acquired pulses with the pulse
counter monitor served as an accumulation
counter.
• By turning on [PCC] (Clearing of pulse counter),
you can clear the accumulated counter value.
Parameters
Item
Input terminal function
Output terminal function
Selection of targets for
pulse string input
detection
Pulse count
compare-match output
ON level
Pulse count
compare-match output
OFF level
Maximum value for pulse
count compare-match
output
Pulse counter monitor
Parameter
[CA-01]~[CA-11]
[CC-01]~[CC-07]
[CA-90]
[CA-97]
[CA-98]
[CA-99]
[dA-28]
0~2147483647
12-24-13
About the inverter function
• The maximum input pulse in the phase coefficient
monitoring mode becomes a maximum of 32 kpps.
(When the duty ratio is approximately 50%)
• An accumulation counter value cannot be stored.
After the power supply is turned on, the value
becomes zero.
• The maximum input pulse in the terminal input
monitoring mode depends on the settings of the
input terminal response functions [CA-41] to
[CA-51].
Data
103
[PLA]: Accepts a pulse input.
104
[PLB]: Accepts a pulse input.
097
[PCC]: Clears the integrated value.
[PCMP]: Outputs pulse
091
compare-match signals.
00
PCNT function
01
Instruction
02
Speed feedback
03
Pulse count
When the number of pulses reaches
0~65535
this set value, Turn on [PCMP].
When the number of pulses reaches
0~65535
this set value, Turn off [PCMP].
A one-shot pulse can be achieved
when the value is 0.
0~65535
When the number of pulses reaches
the set value, the internal counter is
cleared.
Displays the counter integrated value.
Description