Danfoss VLT Active Front End AFE 302 Operating Instructions Manual page 43

Hide thumbs Also See for VLT Active Front End AFE 302:
Table of Contents

Advertisement

Specifications
Relay outputs
Programmable relay outputs
Relay 01 terminal number
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Relay 02 (FC 302 only) terminal number
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum. terminal load (DC-1)
Maximum terminal load (DC-13)
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Minimum terminal load on 1-3 (NC), 1-2 (NO), 4-6 (NC), 4-5 (NO)
Environment according to EN 60664-1
1) IEC 60947 part 4 and 5
The relay contacts are galvanically isolated from the rest of the circuit by reinforced isolation (PELV).
Cable lengths and cross sections
Maximum cross section to control terminals, flexible/ rigid wire without cable end sleeves
Maximum cross section to control terminals, flexible wire with cable end sleeves
Maximum cross section to control terminals, flexible wire with cable end sleeves with collar
Minimum cross section to control terminals
Control card performance
Scan interval
Control characteristics
Resolution of frequency
Repeat accuracy of precise start/stop (terminals 18, 19)
System response time (terminals 18, 19, 27, 29, 32, 33)
Surroundings
Enclosure, frame size D and E
Enclosure, frame size F
Vibration test
Max. relative humidity
Aggressive environment (IEC 60068-2-43
Ambient temperature (with SFAVM switching mode)
- with derating
- at full continuous drive output current
1) For more information on derating, see special conditions in the Design Guide
Minimum ambient temperature during full-scale operation
Minimum ambient temperature at reduced performance
Temperature during storage/transport
Maximum altitude above sea level without derating
Derating for high altitude, see special conditions in the Design Guide
EMC standards, Emission
EMC standards, Immunity
See section on special conditions in the Design Guide.
MG33X402
Operating Instructions
1)
on 1-3 (NC), 1-2 (NO) (Resistive load)
1)
(Inductive load @ cosφ0.4)
1)
on 1-2 (NO), 1-3 (NC) (Resistive load)
1)
(Inductive load)
1)
on 4-5 (NO) (Resistive load)
1)
on 4-5 (NO) (Inductive load @ cosφ0.4)
1)
on 4-5 (NO) (Resistive load)
1)
on 4-5 (NO) (Inductive load)
1)
on 4-6 (NC) (Resistive load)
1)
on 4-6 (NC) (Inductive load @ cosφ0.4)
1)
on 4-6 (NC) (Resistive load)
1)
on 4-6 (NC) (Inductive load)
5% - 95%(IEC 721-3-3; Class 3K3 (non-condensing) during operation
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
Danfoss A/S © Rev. 05/2014 All rights reserved.
1-3 (break), 1-2 (make)
240 V AC, 2 A
240 V AC, 0.2 A
24 V DC, 0.1 A
4-6 (break), 4-5 (make)
400 V AC, 2 A
240 V AC, 0.2 A
24 V DC, 0.1 A
240 V AC, 2 A
240 V AC, 0.2 A
24 V DC, 0.1 A
24 V DC 10 mA, 24 V AC 20 mA
overvoltage category III/pollution degree 2
1.5 mm
1 mm
0.5 mm
0.25 mm
IP 54/Type 12
-25 to +65/70 °C
EN 61800-3, EN 61000-6-3/4, EN 55011
EN 61800-3, EN 61000-6-1/2,
2
60 V DC, 1 A
80 V DC, 2 A
5
5
50 V DC, 2 A
2
/16 AWG
2
/18 AWG
2
/20 AWG
2
/24 AWG
1 ms
±0.003 Hz
≤±0.1 ms
≤ 2 ms
IP 00/Chassis
0.7 g
class H
5
2
Max. 55 °C
1)
Max. 45 °C
1)
0 °C
-10 °C
1,000 m
41