Siemens COMOS Operating Manual page 136

Life cycle engineering and plant asset management
Table of Contents

Advertisement

"Error analysis for 3D objects" plugin
12.3 Interface of the plugin
● Table at the top:
Contains all attributes from the "3D geometry" tab whose 3D mode is active.
● Table at the bottom:
Contains the 3D attributes required for which a corresponding attribute could not be found
at the pipe part. The values can be drawn from standard tables or are optional and do not
have to be created at the object itself.
Structure of the "Bulk analysis" tab
The "Bulk analysis" tab has the following structure:
136
Column
"Attribute name"
"Description"
"Value"
"Result"
"Error message"
"Required attribute"
Description
Self-explanatory.
Self-explanatory.
Self-explanatory.
This field normally includes concrete values or
calculation formulae.
The result of the geometry calculation for the at‐
tribute
Type of error if the attribute could not be calcu‐
lated
Green check mark: The value of the attribute is
necessary for the 3D display mode.
Red cross: The value is not present and the com‐
ponent is viewed as "not valid" in these dimen‐
sions.
No symbol: The value of the attribute is not nec‐
essary for the 3D display mode.