Procedure
1. To assign a new legend description, proceed as follows:
– Double-click in a cell of the "Legend" column.
– Enter the new description in the cell.
2. To assign a new color, proceed as follows:
– Click with the left mouse button in a cell in the "Color" column.
– Select a new color in the "Color" window.
3. To save your entries, click the "Close" button.
8.6.4

Modifying the nominal diameter range

The configuration of the nominal diameter range on the "Branch table" tab has the same effect
as the configuration on the "Nominal diameters" tab.
Procedure
1. Click the button [...] of the required branch part in the "Nominal diameter range" column.
2. In the lower half of the "Branch table" tab, select the tab of the required branch part.
The window with the nominal diameter table of the branch part opens.
3. To add a nominal diameter to the nominal diameter range, select the "Select" command in
the context menu of an empty white cell.
4. To exclude a nominal diameter from the nominal diameter range, select the "Deselect"
command in the context menu of an empty white cell.
5. Save your entries.
Result
The nominal diameter range of the branch part is modified accordingly:
● In the branch table
● On the "Nominal diameters" tab
8.6.5

Branch table for PDMS pipe specs

When you load a PDMS pipe spec in the PipeSpec Designer, the following deviations apply
compared to the COMOS pipe specs:
● Objects with the GTypes "TEE" and "OLET" are permitted as branches. The function code
is irrelevant.
● There are no preselected components. This means there is only the "Show all available
components" display mode.
PipeSpec Designer
Operating Manual, 09/2014, A5E32076948-AA
Configuring pipe specs
8.6 "Branch table" tab
99