Siemens COMOS Operating Manual page 137

Life cycle engineering and plant asset management
Table of Contents

Advertisement

● Field "Start object":
A link to one of the following base objects:
– Pipe part from the pipe part catalog
– Structure object from the pipe part catalog
– Pipe spec element
– Pipe spec
If there are no base objects underneath the start object, the start object is analyzed.
If there are more base objects underneath the start object, they are analyzed recursively.
● "Unit location" field:
– Link to an engineering object of the "Device" system type whose creation mode is "Free"
– Optional
– Requirement: "Create 3D" option is activated.
– The 3D objects generated are created underneath the object linked here.
● "Error geometry" field:
– Link to a 3D base object
– Optional
– Requirement: The "Create 3D" option is activated and the "Unit location" reference is
– For objects whose geometry could not be calculated or could not be calculated correctly,
● "Create 3D" option:
– Optional
– Requirement: "Unit location" reference is set.
– Active: 3D objects are created for all objects, even objects whose geometry was not
● "Invalid only" option:
– Optional
– Requirement: "Create 3D" option is activated.
– Active: 3D objects are only created for the objects whose geometry could not be
● "Start analysis" button:
Starts the analysis. Data is written to the results table even while the analysis is still in
progress.
● "Cancel" button:
Cancels the analysis.
PipeSpec Designer
Operating Manual, 09/2014, A5E32076948-AA
and which has the "Coordinate system definition" tab
set.
3D objects are generated with the base object linked here.
calculated correctly. The 3D objects can be displayed in the Viper 3D Editor.
calculated correctly.
"Error analysis for 3D objects" plugin
12.3 Interface of the plugin
137

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents