Front Panel Configuration - Rice Lake IQ plus 350 Installation Manual

Digital weight indicator version 1.0. revolution scaleware configuration utility
Table of Contents

Advertisement

3.1.3
Front Panel Configuration
The IQ plus 350 indicator can be configured using a series of menus accessed through the indicator front panel
when the indicator is in setup mode. Table 3-1 summarizes the functions of each of the main menus.
Menu
CONFIG
Configuration
FORMAT
Format
CALIBR
Calibration
SERIAL
Serial
PROGRM
Program
P FORMT
Print Format
DIG IN
Digital Input
ALGOUT
Analog Output
VERSION
Version
ZERO
Four front panel keys are used as directional keys to navigate through the menus in setup mode (see Figure 3-2).
The
UNITS
( ) and
PRINT
GROSS/NET
( ) move up and down (vertically) to different menu levels. The
key for selecting parameter values within the menus. A label under each of these keys identifies the direction
provided by the key when navigating through the setup menus.
1
Level
st
Parameter
2
Level
nd
Parameter
Default value
When moving through values below the first menu level, press
above. Press
or
Configure grads, zero tracking, motion band, tare function, and digital filtering parameters.
Set format of primary and secondary units, display rate.
Calibrate indicator. See Section 4.0 on page 25 for calibration procedures.
Configure EDP and printer serial ports.
Set power-up mode, regulatory mode, and consecutive number values.
Set print format used for gross and net tickets. See Section 6.0 for more information.
Assign digital input functions.
Configure analog output module. Used only if analog output option is installed.
Display installed software version number.
Table 3-1. IQ plus 350 Menu Summary
GROSS
NET
B/N
SETUP MODE KEY FUNCTIONS
Figure 3-2. Front Panel Key Functions in Setup Mode
( ) keys scroll left and right (horizontally) on the same menu level;
Value
Value
to move to the next parameter on the level above.
Figure 3-3. Setup Mode Menu Navigation
Menu Function