Analog Output Menu; Version Menu - Rice Lake IQ plus 350 Installation Manual

Digital weight indicator version 1.0. revolution scaleware configuration utility
Table of Contents

Advertisement

3.2.8

Analog Output Menu

The ALGOUT menu is used only if the analog output option is installed. If the analog output option is installed,
configure all other indicator functions and calibrate the indicator (see Section 4.0 on page 25) before configuring
the analog output. See Section 7.7 on page 40 for analog output calibration procedures.
CONFIG
XXXXXXX
FORMAT
CALIBR
SOURCE
OFFSET
0%
GROSS
20%
NET
ALG OUT Menu
Parameter
Choices
Level 2 submenus
SOURCE
GROSS
NET
OFFSET
0%
20%
ERRACT
FULLSC
HOLD
ZEROSC
MIN
000000
number
MAX
010000
number
TWZERO
TWSPAN
3.2.9

Version Menu

The VERS menu is used to check the software version installed in the indicator. There are no parameters
associated with the Version menu: when selected, the indicator displays the installed software version number.
CONFIG
FORMAT
XXXXXXX
24
IQ plus 350 Installation Manual
SERIAL
PROGRM
ERRACT
FULLSC
HOLD
ZEROSC
Figure 3-12. Analog Output Menu
Specifies the source tracked by the analog output.
Zero offset. Selects whether the analog output supplies voltage (0–10 V) or current (4–20 mA)
output. Select 0% for 0–10 V output; select 20% for 4–20 mA output.
Error action. Specifies how the analog output responds to system error conditions.
Possible values are:
FULLSC: Set to full value (10 V or 20 mA)
HOLD: Hold current value
ZEROSC: Set to zero value (0 V or 4 mA)
Specifies the minimum weight value tracked by the analog output. Specify a value in the range
0–600 000.
Specifies the maximum weight value tracked by the analog output. Specify a value in the range
0–600 000.
Tweak zero. Adjust the analog output zero calibration. Use a multimeter to monitor the analog
output value. Press and hold
Tweak span. Adjust the analog output span calibration. Use a multimeter to monitor the analog
output value. Press and hold
Table 3-8. Analog Output Menu Parameters
CALIBR
SERIAL
PROGRM
Figure 3-13. Version Menu
PFORMT
XXXXXXX
DIG IN
XXXXXXX
ALGOUT
MIN
MAX
000000
10000
number
number
Description
or
to adjust the output. Press
or
to adjust the output. Press
PFORMT
XXXXXXX
DIG IN
XXXXXXX
VERS
TWZERO
TWSPAN
to save the new value.
to save the new value.
ALGOUT
XXXXXXX
XXXXXXX
VERS
Software
version

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents