Honeywell UDC 3300 Product Manual page 111

Universal digital controller
Hide thumbs Also See for UDC 3300:
Table of Contents

Advertisement

Lower Display
Prompt
ALG1 INA
ALG1 INB
ALG1 INC
PCO SEL
PCT CO
ATM PRES
ALG1 BIAS
4/00
Upper Display
Range of Setting
or Selection
INP 1
INP 2
LP1OUT
LP2OUT
IN AL1
IN AL2
INP 3
INP 1
INP 2
LP1OUT
LP2OUT
IN AL1
IN AL2
INP 3
NONE
INP 1
INP 2
LP1OUT
LP2OUT
IN AL1
IN AL2
INP 3
DISABL
ONLINE
0.020 to 0.350 (fractional
percent of CO)
590.0 to 760.0 (mm Hg)
-999 to 9999 floating (in
engineering units)
UDC 3300 Process Controller Product Manual
Parameter
Definition
ALGORITHM 1, INPUT A SELECTION will represent one
of the available selections.
Input 1
Input 2
Output 1 (NOTE 1)
Output 2
Input Algorithm 1
Input Algorithm 2
Input 3
ALGORITHM 1, INPUT B SELECTION will represent one
of the available selections.
Input 1
Input 2
Output 1 (NOTE 1)
Output 2
Input Algorithm 1
Input Algorithm 2
Input 3
ALGORITHM 1, INPUT C SELECTION will represent one
of the available selections.
None
Input 1
Input 2
Output 1 (NOTE 1)
Output 2
Input Algorithm 1
Input Algorithm 2
Input 3
PERCENT CARBON SOURCE allows a live Input 3 value
to be substituted for the static % CO value (PCT CO).
DISABLED
ONLINE—Input 3 must be enabled
PERCENT CARBON is only applicable when Carbon
Potential is selected. Enter the value in percent carbon
monoxide that is applicable for the enriching gas used in
fractional form.
FOR EXAMPLE:
Natural Gas = 20.0 % CO, then setting is 0.200
Propane Gas = 23.0 % CO, setting is 0.230
ATMOSPHERIC PRESSURE COMPENSATION is only
applicable when Relative Humidity is selected. Enter the
value of the atmospheric pressure of the process.
INPUT ALGORITHM 1 BIAS—Does not apply to
selections: FFWRD, FFWDM2, HISEL, or LOSEL.
99