StorEdge-related Errors Codes

StorEdge-related Errors Codes
This section describes the error messages that are specific to the StorEdge solution. For 
troubleshooting errors that are not listed below, refer to 
http://www.solaredge.com/sites/default/files/se-inverter-installation-guide-error-
codes.pdf contact SolarEdge support. For the general SolarEdge troubleshooting refer 
to the codes in the previous section. 
Error
Error
code
code
CPU
CPU v3.19
v3.18 and
and
below
above
179, 180
2xB3, 2xB4 Backup Consumption Too High
181
2xB5
183
2xB7
184
2xB8
185
3x6B
186
3x6B
100
LCD Message
Connection Unit
HW Error
Connection Unit
Communication Error
Connection Unit
Temp. Too High
Meter Comm. Error
Battery Comm Error
StorEdge Inverter Installation Guide MAN-01-00390-1.1
Cause and Troubleshooting
Inverter production stopped due to backed-up
loads' consumption exceeding product rating.
Shutdown non-essential loads to reduce power
consumption.
Check all the communication cable between
the StorEdge Connection Unit and the digital
board in the inverter.
There is a faulty wire connection or an internal
error.
Check the communication cable between
o
the StorEdge Connection Unit and the
digital board in the inverter.
Check that the StorEdge Connection Unit
o
LEDs are ON.
Inverter production stopped due to StorEdge
Connection Unit overheating or due to internal
fan malfunction.
Clean the StorEdge Connection Unit fan
o
If the fan is malfunctioning, replace the fan
o
Refer to Meter Troubleshooting on page 93.
Check the wiring to the battery and the
o
battery DIP switch configuration (refer to
Connecting to the Battery on page 32 and
DIP Switch Setup on page 36.
Check the termination DIP switches on the
o
inverter communication board (refer to
DIP Switch Setup on page 36 .
Check the battery setup in the RS485-Conf
o
screen (refer to Configuring the RS485 Bus
for Battery and Meter Connection on page
81).