You may refer to the SolarEdge web site (www.solaredge.com) for the most updated version. All company and brand products and service names are trademarks or registered trademarks of their respective holders.
Page 3
Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance may void the user’s authority to operate the equipment. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Revision History 3 Revision History Version 1.1 (September 2019) Added Running a Battery Self-test on page 41. Version 1.0 (July 2019) First version of this guide StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Step 1: Activating the Installation Step 2: Commissioning and Configuring the Installation Step 3: Verifying Proper Activation and Commissioning Configuring Communication with the Battery and Energy Meter Running a Battery Self-test Configuring StorEdge Applications StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 6
Adding, Removing, or Replacing Power Optimizers Appendix C: Powering the LG Chem Battery Off and On Appendix D: Connecting and Powering Systems with a DC Disconnect Switch Appendix E: SafeDC™ Support Contact Information StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Denotes additional information about the current subject. IMPORTANT SAFETY FEATURE Denotes information about safety issues. Disposal requirements under the Waste Electrical and Electronic Equipment (WEEE) regulations: NOTE Discard this product according to local regulations or send it back to SolarEdge. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
CAUTION! HEAVY OBJECT. To avoid muscle strain or back injury, use proper lifting techniques, and if required - a lifting aid. NOTE Use PV models rated according to IEC 61730 class A. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 9
NOTE A SolarEdge inverter may be installed in a site with a generator. SolarEdge requires installing a physical or electronic interlock, which will signal to the inverter when the grid has been disconnected. Interlock procurement, installation, maintenance and support are the responsibility of the installer.
Page 10
This unit must be operated under the specified operating conditions as described in the technical specifications supplied with the unit. NOTE The battery used must be NRTL certified. NOTE For battery decommissioning and disposal, follow the manufacturer requirements and instructions. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Smart Energy Management applications, such as: export limitation and maximizing self-consumption. One battery - a DC-coupled battery designed to work with the SolarEdge system. Figure 1: StorEdge system components StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Additional References This document describes basic system connection and configuration - PV system (power optimizer strings), one inverter, one battery, and one meter. For additional configuration options refer to the StorEdge Solution Applications - Connection and Configuration Guide, available at: https://www.solaredge.com/sites/default/files/storedge_applications_ connection_and_configuration_guide.pdf...
Store the inverter in a dry place where ambient temperatures are -25°C to +65°C / -13°F to 149°F. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Drilling holes in the model frame should be done according to the model manufacturer instructions. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Installation Guidelines CAUTION! Installing a SolarEdge system without ensuring compatibility of the model connectors with the optimizer connectors may be unsafe and could cause functionality problems such as ground faults, resulting in inverter shut down. To ensure mechanical compatibility of the power optimizers’ connectors with the PV model’...
Page 16
Figure 2: Power optimizer clearance When installing modules in a confined space, for example, if installing Building- integrated photovoltaic (BIPV) modules, ventilation measures may be needed to StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Images are for illustration purposes only. Refer to the label on the product to identify the plus and minus input and output connectors. For each of the power optimizers: (1) Not applicable to smart models. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
2. Connect the rest of the power optimizers in the string in the same manner. WARNING! If using a dual-input power optimizer and some inputs are not used, seal the unused input connectors with the supplied pair of seals. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Make sure the PVmodels are exposed to sunlight during this process. The power optimizer will only turn ON if the PV model provides at least 2W. In SolarEdge systems, due to the introduction of poweroptimizers between the PV models and the inverter, the short circuit current I and the open circuit voltage V hold different meanings from those in traditional systems.
Identifying the Inverter Refer to the sticker on the inverter that specifies its Serial Number and its Electrical Ratings. Provide the serial number when contacting SolarEdge support. The serial number is also required when opening a new site in the monitoring platform.
OFF (0) - Turning this switch OFF reduces the power optimizer voltage to a low safety voltage and inhibits exportation of power. When this switch is OFF, the control circuitry remains powered up. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 22
Red ON - system error (1) Blinking = Turns ON and OFF for the same duration (2) Flickering = Turns ON for 100 mS and turns OFF for 5 seconds (3) Alternating = alternate LED flashes StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 23
Blinking (Safe DC) No S_OK: OFF OFF (0) S_OK: ON Inverter is OFF Blinking Blinking (DC not safe) No S_OK: OFF Inverter configuration ON / P or reboot StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 24
0 - 33 % production as ON (1) percentage of Percentage of AC rated peak AC Production: output power 33 - 66 % Percentage of AC Production: 66 - 100 % StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
CAUTION! SolarEdge inverters and power optimizers can be installed at a minimum distance of 50 m/ 164 ft from the shoreline of an ocean or other saline environment, as long as there are no direct salt water splashes on the inverter or power optimizer.
Page 26
When installing inverters one above of the other, leave at least 40 cm (16") between inverters. 3. Position the mounting bracket against the wall/ pole and mark the drilling hole locations (refer to for inverter and mounting bracket dimensions). StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 27
6. Optionally, secure the Connection Unit bracket to the wall/pole, using 3 screws: NOTE In case of inverter replacement with the Connection Unit still mounted, it is recommended to use all 3 holes. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 28
e. Fasten the Connection Unit bracket using a standard bolt. 7. Insert the screws at the top of the inverter brackets and fasten the brackets together. 8. Verify that all the brackets are firmly attached to the mounting surface. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Mark polarity on DC cables. Mount the battery. Connect all the wires to the battery connection panel. Tie and wrap the cables to avoid pulling them out during mounting. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
CAUTION! When removing the covers, make sure not to damage internal components. SolarEdge will not be held responsible for any components damaged as a result of incautious cover removal. 4. Strip 58 mm / 2.32'' of the external cable insulation and strip 8 mm / 0.32'' of the internal wire insulation.
Page 31
1.5 N*m / 0.88-1.1 lb*ft. 9. Check that the wires are fully inserted and cannot be pulled out easily. 10. Tighten the AC cable gland with a torque of 2.8-3.3 N*m / 2.0-2.4 lb*ft. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
PV array modules is acceptable. NOTE SolarEdge’s fixed input voltage architecture enables the parallel strings to be of different lengths. Therefore, they do not need to have the same number of power optimizers, as long as the length of each string is within the permitted range.
Page 33
3. Make sure the RS485-2 DIP switch (the right switch) is OFF. 4. Make sure the Energy Meter's DIP switch 2 is ON. 5. Proceed with connection only after installing the battery, as explained in Connecting the Battery on page 33. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
For DC power - a pair of PV DC cables, 6 (4-6) mm , 600V insulated, with MC4 connectors at one end To connect the battery and the StorEdge Interface: 1. Connect one end of the communication cable to the battery, as explained in the manual that comes with the battery.
Page 35
Figure 17: DC cable connection - LG Chem battery to inverter 9. Close the inverter and Connection Unit covers with the Allen screws. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
2. Open SetApp and follow the instructions on the screen (scan the inverter bar-code; move the ON/OFF/P switch to P position and release within 5 sec. back to ON (1) position). SetApp creates a Wi-Fi connection, upgrades the inverter CPU firmware and activates the inverter. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Country and Language › Pairing › Communication › Device Manager › Maintenance › Information › Status If the inverter has already been activated and commissioned: StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 38
1. From the main menu, select Pairing. 2. Tap Start Pairing. 3. When Pairing Complete is displayed, the system startup process begins: StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 39
The communication option used by the inverter to communicate with the monitoring platform. The communication option used to communicate between multiple SolarEdge devices or other external non-SolarEdge devices, such as electricity meters or loggers. 2. Tap the Server red arrow to set the communication method to be used for communication between devices and the SolarEdge monitoring platform.
Page 40
Activate Standby Mode: Enables/disables Standby Mode - for remote commissioning. Board Replacement: Backs up and restores the system parameters, including energy counters; Used during board replacement according to the instructions supplied with replacement kits. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
DSP 1/2 Version: The digital board firmware version NOTE Please have these numbers ready when you contact SolarEdge Support. Serial Number: The inverter serial number as appears on the enclosure sticker Error Log: Displays the last five errors, and enables resetting (clearing) the log...
0, check communication with the CT. 3. Select Meter 1 è Meter Function è Export+Import (E+I). Running a Battery Self-test Run a battery self-test to check the battery's charge and discharge functionality. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
ON – the battery is controlled for maximized self-consumption Battery OFF periods can be configured to extend battery lifetime by minimizing the number of shallow discharges (for example at nighttime or during the winter). StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
) may appear at the top left corner of a status cell, indicating a temporary status, such as a connection process. When the process is complete, the icon disappears and a constant status message is displayed. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 45
If XXX and YYY are not equal, there may be a problem in one or more power optimizers. S_OK: The connection to the monitoring platform. (Server Connected appears only if the inverter is connected to the monitoring platform). StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 46
Note , available on the SolarEdge website at https://www.solaredge.com/sites/default/files/application_note_ power_control_configuration.pdf. Limit: The inverter maximum output power Country: The selected country and grid setting Voltage (Vdc): The DC input voltage Temp (°C or °F): The inverter heat sink temperature StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 47
› Switch Off. Production disabled › Commissioning Site status: Production: The AC output power Limit: Limitation setting (Export or Production) Inverters: Number of connected inverters in the cluster, including the master StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 48
Number of devices connected out of all devices Temporarily displayed (with a clock sign): Initializing communication Connecting to a network Connecting to SolarEdge servers Error message (with the sign) StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 49
If the meter is installed at the production point, this value is the energy produced by the site. If the meter is installed at the grid connection point, this value is the energy exported to the grid. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
NOTE Monitoring the site requires connecting the inverter to the monitoring platform, using any of the wired or wireless options available from SolarEdge. Refer to Setting Up Communication to the Monitoring Platform on page 53. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 51
To display a physical layout, you need to map the locations of the installed power optimizers. To map the locations, use one of the methods described in the next sections. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 52
If you have not yet signed up, go to https://monitoring.solaredge.com/solaredge- web/p/createSelfNewInstaller. 2. Fill out all required information in the screen, which includes information about your installation, as well as details about its logical and physical mapping. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 53
Once the form is completed, use the Mapper to scan the 2D codes and create the map in the monitoring platform. Optionally, you can send the sticker sheet to SolarEdge Support for physical layout creation. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Only communication products offered by SolarEdge are supported. Ethernet Ethernet is used for a LAN connection. For connection instructions refer to Creating an Ethernet (LAN) Connection on page 56. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 55
Communication Options RS485 RS485 is used for the connection of multiple SolarEdge devices on the same bus in a master-slave configuration. RS485 can also be used as an interface to external devices, such as meters and third party data loggers.
The communication board has the following connectors: Standard RJ45 terminal block for Ethernet connection RS485 connector The SolarEdge Wi-Fi antenna, ZigBee or Cellular Plug-ins can be connected to the communication board for optional wireless connection. Figure 18: Communication board connectors Removing the Inverter Cover 1.
CAUTION! When removing the inverter cover, make sure not to damage the internal components. SolarEdge will not be held responsible for any components damaged as a result of incautious cover removal. Removing the Connection Unit Cover 1. Turn OFF the AC breaker of the distribution panel and the safety switch (if applicable).
Page 58
T568A White/Orange White/Green Transmit+ Orange Green Transmit- White/Green White/Orange Receive+ Blue Blue Reserved (1) The inverter connection does not support RX/TX polarity change. Supporting crossover Ethernet cables depends on the switch capabilities. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 59
SolarEdge monitoring platform. 10. The inverter is configured by default to LAN. (1) The inverter connection does not support RX/TX polarity change. Supporting crossover Ethernet cables depends on the switch capabilities. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
RS485 chain; make sure the grounding wire is not in contact with other wires. For inverters with a Connection Unit, connect the grounding wire to the grounding bus-bar in the Connection Unit. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 61
The same color wire is used for all A pins the same color for all B pins and the same color for all G pins The wire for G is not from the same twisted pair as A or B. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 62
9. Push the RS485 terminal block firmly all the way into the connector on the right side of the communication board. 10. Terminate the first and last SolarEdge device in the chain by switching a termination DIP-switch inside the inverter to ON (move the left switch up). The switch is located on the communication board and is marked SW1.
2. Check that S_OK - Server Connected status appears in the main inverter section. 3. Scroll down to the Communication section and check that the communication options are as required. For more information refer to Communication Status on StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 64
Chapter 7: Setting Up Communication to the Monitoring Platform 63 page 47. Communication RS485-1 RS485-2 Modbus SE Slave Connected 2 of 2 None Cellular Wi-Fi ZigBee StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
1. Open the site dashboard and click the Layout icon. 2. Right-click the inverter and select Info from the menu. The inverter details window is displayed. 3. Click the Errors tab. The list is displayed. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Troubleshooting RS485 Communication If the message RS485 Master Not Found appears in the Status screen, check the connections to the master device and fix if required. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 67
3. Check that the selected communication option is properly configured. 4. Use a method independent of the SolarEdge device to check whether the network and modem are operating properly. For example, connect a laptop to the Ethernet router and connect to the Internet.
(not applicable to smart String voltage not 0V but lower than models). number of optimizers Connect the models to the optimizer inputs. String reverse polarity. Check string polarity using a voltmeter and correct if needed. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Page 69
3. Contact SolarEdge Support. Do not continue before finding the problem and replacing the malfunctioning power optimizer. If a malfunction cannot be bypassed or resolved, skip the malfunctioning power optimizer, thus connecting a shorter string. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
Appendix A: Mechanical Specifications Appendix A: Mechanical Specifications The following figure provides inverter dimensions in mm [in]. Figure 24: SE2200H-SE6000H inverter dimensions StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
70 Appendix B: Replacing and Adding System Components This appendix includes replacement procedures for the SolarEdge system components. NOTE If you are permanently disassembling the installation or part of it, make sure to use the disposal methods dictated by local regulations.
Page 72
11. Insert the wires from the Connection Unit into the openings in the inverter and the ferrite bead. 12. Fasten the two clips securing the Connection Unit to the inverter. 13. Reconnect the cables: Follow the instructions of Installing the Inverter on page 19. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
6. In the monitoring platform, use the Replace button in the logical layout tab (in site Admin). Replace the serial number of the removed power optimizer with the serial number of the newly installed power optimizer. Refer to https://www.solaredge.com/sites/default/files/se- monitoring-portal-site-admin.pdf StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
1. Turn off the circuit breaker. 2. Turn off the disconnect/auxiliary power switch. To power the battery back on: 1. Turn on the disconnect/auxiliary power switch. 2. Turn on the circuit breaker. StorEdge Single Phase Inverter with HD-Wave Technology MAN-01-00627-1.1...
74 Appendix D: Connecting and Powering Systems with a DC Disconnect Switch To power off/on a StorEdge system that includes a Single Phase Inverter with HD-Wave Technology and a DC disconnect switch (external or integrated), do the following: To power off: 1.
Page 76
The switch must be able to handle the maximum currents specified in the inverter and StorEdge Interface specifications. Maintain the maximum distance between the StorEdge Interface and inverter prescribed by the local regulations or the SolarEdge specifications - the shortest distance of the two. ...
ON/OFF/P switch is turned to OFF, the DC voltage drops to a safe voltage of per optimizer. The SolarEdge inverters are certified for compliance with the following standards as disconnection devices for PV generators, meaning that they can replace a DC disconnect: IEC 60947-3:1999 + Corrigendum: 1999 + A1:2001 + Corrigendum 1:2001 + A2:2005;...
System configuration information, including the type and number of modules connected and the number and length of strings. The communication method to the SolarEdge server, if the site is connected. The product's software version as it appears in the status screen.
Page 79
(1) Wi-Fi connectivity requires an external antenna. For more information refer to: https://www.solaredge.com/sites/default/files/se-wifi-zigbee-antenna-datasheet.pdf (2) For more information refer to: https://www.solaredge.com/sites/default/files/se-zigbee-plug-in-wireless-communication-for-setapp-datasheet.pdf (3) Import/Export meter is required for Export Limitation and for controlled Excess Solar charging MAN-01-00628-1.0 StorEdge Single Phase Inverter with HD-Wave Technology and SetApp Configuration Technical Specifications...
Page 80
-40 to +60 ˚C Protection Rating IP65 — Outdoor and Indoor (1) Full power up to at least 50˚C. For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf MAN-01-00628-1.0 StorEdge Single Phase Inverter with HD-Wave Technology and SetApp Configuration Technical Specifications...