Battery Status

PWR Limit: The inverter maximum output power set by one of the power limiting options: 
 
RRCR 
 
o
Smart energy manager (Feed-in limitation) 
 
o
P(f)
 
o
P(U)
 
o
Q(U) 
 
o
Cos Phi: The ratio between active to reactive power 
 
Power Prod: The power produced by the inverter 
 
For more information, refer to the Power Control Application Note, available on the 
SolarEdge website at http://www.solaredge.com/files/pdfs/application_note_power_
control_configuration.pdf.
Battery Status
This screen is displayed only when the battery is configured, and shows the battery 
identification information, its charging status and power, and the operating mode.
B S N :
X X X X X X X X X
S O E :
8 9 %
T o t a l :
S t a t e :
BSN: Battery serial number
 
ID: Battery identification - should be 24 as set up above
 
SOE: State of Energy - the battery capacity percentage (calculated as Available Energy\Max. Energy)
 
PWR: The charging or discharging power (in Watts) according to the battery state (see below)
 
Total: The total discharged energy in Watt/hour
 
State: The battery status: Charging/ Discharging, Idle, Init (pre-heating) or Fault <error code>.
 
 
68
I D : 1 5
P W R :
2 W
< x > W h
C h a r g i n g
StorEdge Inverter Installation Guide MAN-01-00390-1.1