Fuse Replacement; Battery Replacement - SolarEdge StorEdge Installation Manual

For smart energy management using lg chem batteries
Hide thumbs Also See for StorEdge:
Table of Contents

Advertisement

Fuse Replacement

Fuse Replacement
Replacement kits are available from SolarEdge or you can use other fuses with identical ratings.
 1.  Turn OFF the inverter ON/OFF switch, and wait until the LCD indicates that the DC voltage is safe 
(<50V), or wait five minutes before continuing to the next step.
WARNING!
If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five
minutes for the input capacitors of the inverter to discharge.
 2.  Turn OFF the StorEdge Connection Unit  and the AC switch of the distribution panel. 
 3.  Open and remove the StorEdge Connection Unit  cover.
 4.  For StorEdge Connection Unit - Open and remove the internal transparent cover.
 5.  Remove the faulty fuse from the upper board of the StorEdge Connection Unit   a nd replace with a 
new fuse.
 6.  Close the StorEdge Connection Unit   c over(s).

Battery Replacement

To disconnect or replace a battery:
 1.  Turn OFF the StorEdge Connection Unit ON/OFF switch.
 2.  Turn OFF the inverter ON/OFF switch, and wait until the LCD indicates that the DC voltage is safe 
(<50V), or wait five minutes before continuing to the next step.
WARNING!
If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five
minutes for the input capacitors of the inverter to discharge.
 3.  Turn OFF the AC switch at   t he distribution panel. 
106
Figure 51: StorEdge Connection Unit fuses
StorEdge Inverter Installation Guide MAN-01-00390-1.1