Attachment And Installation; Requirements For The Tractor; Connections, Sockets; Power Supply - Rauch QUANTRON-A AXIS-M 20 Q Instruction Manual

Table of Contents

Advertisement

3

Attachment and installation

3.1

Requirements for the tractor

Before installing the control unit, check to make sure your tractor meets the fol-
lowing requirements:
A minimum voltage of 11 V is essential at all times, even if multiple loads are
connected simultaneously (e. g. air conditioning system, lights).
The PTO speed can be set to 540 rpm and must be maintained (basic re-
quirement for correct working width).
On tractors without load-switchable gears, the forward speed must be selected
by using the correct gear ratio in such a way that it corresponds to a PTO speed
of 540 rpm.
A 7-pin socket (DIN 9684-1/ISO 11786). The control unit receives the pulse
for the current forward speed through this socket.
The 7-pin socket for the tractor and the forward speed sensor can be obtained
as an expansion kit (option), see chapter Special Equipment.
3.2

Connections, sockets

3.2.1

Power supply

The control unit is supplied with power from the tractor via the 3-pin power supply
socket (DIN 9680/ISO 12369).
Figure 3.1:
PIN assignment of power socket
Attachment and installation
NOTICE
NOTICE
[1] PIN 1: not required
[2] PIN 2: (15/30): +12 V
[3] PIN 3: (31): mass
3
19

Hide quick links:

Advertisement

Table of Contents
loading