Rauch E-CLICK Instruction Manual

Rauch E-CLICK Instruction Manual

For axis and mds
Hide thumbs Also See for E-CLICK:

Advertisement

Quick Links

INSTRUCTION MANUAL
Please read carefully
before using the ma-
chine.
Keep for future reference.
This instruction manual/assembly in-
struction is to be considered as part of
the machine. Suppliers of new and se-
cond-hand machines are required to
document in writing that the instructi-
on manual/assembly instruction was
delivered with the machine and han-
ded over to the customer.
Original instructions
c
5901360-
-en-0519

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E-CLICK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rauch E-CLICK

  • Page 1 INSTRUCTION MANUAL Please read carefully before using the ma- chine. Keep for future reference. This instruction manual/assembly in- struction is to be considered as part of the machine. Suppliers of new and se- cond-hand machines are required to document in writing that the instructi- on manual/assembly instruction was delivered with the machine and han- ded over to the customer.
  • Page 2: Technical Improvements

    Foreword Dear customer, By purchasing the control unit E-CLICK for the mineral fertiliser spreaders AXIS and MDS, you have shown confidence in our product. Thank you! We want to justify your trust. You have purcha- sed a powerful and reliable control unit. Our customer service is always at your disposal, should any problems arise.
  • Page 3: Table Of Contents

    Spreading using E-CLICK ........
  • Page 4 Table of Contents...
  • Page 5: User Instructions

    User instructions About this operating manual This operating manual is an integral part of the control unit E-CLICK. The manual contains important instructions for a safe, appropriate and economic use as well as maintenance of the control unit. Compliance with its stipulations helps to avoid risks, reduce maintenance costs and downtime and to increase the machine's reliability and service life.
  • Page 6 User instructions Warning severity level The degree of danger is indicated by the signal word. The levels are classified as follows: n DANGER Type and source of danger This warning warns of a danger posing an immediate threat to the health and life of persons.
  • Page 7: Instructions And Procedures

    User instructions 1.2.2 Instructions and procedures Steps that the operator must carry out are shown as a numbered list. 1. Instruction for action step 1 2. Instruction for action step 2 Instructions involving only one step are not numbered. The same applies for action steps that do not have a specific sequence.
  • Page 8 User instructions...
  • Page 9: Layout And Function

    Layout and function Layout and function Overview of supported mineral fertiliser spreader versions AXIS C MDS 10.1 C  AXIS 20.1/20.2 C MDS 11.1 C   AXIS 30.1/30.2 C MDS 12.1 C   AXIS 40.1/40.2 C MDS 17.1 C ...
  • Page 10: Layout Of Control Unit - Overview

    Layout and function Layout of control unit - overview Figure 2.1: E-CLICK control unit Description Function Control panel Consists of toggle switches for controlling the unit and multicolour LEDs for displaying machine conditions. Machine cable plug 4-pin plug connector for connecting the machine connector cable to the actuators.
  • Page 11: Operating Elements

    Layout and function Operating elements Use the two toggle switches on the E-CLICK control unit to open and close the metering slides while spreading. Figure 2.2: Arrangement of toggle switches [1] Toggle switch left: Controls the left metering slide [2] Toggle switch right: Controls the right metering slide...
  • Page 12: Display

    Layout and function Display Multicolour LEDs on the display area of the E-CLICK show the condition of the metering slides. Changes in colour show whether the metering slides are open, closed or in motion. Figure 2.3: E-CLICK multicolour LEDs [1] LED condition actuator left...
  • Page 13: Nameplate

    Layout and function Nameplate A nameplate is attached to the back of the E-CLICK control unit where you can find important information about your unit. NOTICE Always have this information ready when contacting your RAUCH point of contact! E-CLICK technical data...
  • Page 14 Layout and function...
  • Page 15: Attachment And Installation

    Attachment and installation Attachment and installation Tractor requirements Before attaching the control unit, check that your tractor meets the following requirements: A minimum voltage 11 V must be guaranteed at all times, even when several  consumers are connected at the same time (e. g. air conditioning, lights). Connections, sockets Power supply The control unit is supplied with power from the tractor using the 3-pin power...
  • Page 16: Attaching The Control Unit

    Attaching the control unit Perform the task steps in the following order. 1. Install the holder as shown in Step 1. 2. Tightly screw the installed holder onto the E-CLICK control unit with the four fixing screws and washers (Step 2). Figure 3.2: Installing the unit holder 3.
  • Page 17: Connecting The Control Unit

    Attachment and installation Connecting the control unit Perform the task steps in the following order. 1. Connect the 4-pin machine cable with its counterpart on the E-CLICK control unit. 2. Connect the E-CLICK control unit power supply with the power socket.
  • Page 18 Attachment and installation...
  • Page 19: Operation E-Click

    A minimum voltage of 11 V is guaranteed.  NOTICE The control unit E-CLICK is ready to operate once it is connected to the on- board power supply of your tractor. Separate activation is not required! n CAUTION Risk of injury caused by ejected fertiliser In the event of faults, the metering slide could open unexpectedly en route to the spreading location.
  • Page 20: Switching Positions Of The Toggle Switches

    In order that the actuator motors are not overloaded, the actuators are switched off automatically when moving against a blockade. NOTICE Requirements for spreading with the control unit E-CLICK: The slider openings on the mineral fertiliser spreader are set properly! NOTICE The toggle switches have 3 locking switching positions.
  • Page 21: Adjusting The Application Rate

    There is the risk of personal injuries due to moving machine parts.  Before driving to the spreading location, the control unit E-CLICK must be disconnected from the on-board power supply! 1. Set the required scale point on the slide operation of your mineral fertiliser spreader.
  • Page 22: Reference Run

    NOTICE The LEDs go out if you switch to the Neutral position while moving and interrupt the movement of the actuators this way. The control unit E-CLICK is not able to identify the state of the actuators. Perform new reference run.
  • Page 23: Spreading Using E-Click

    Operation E-CLICK Spreading using E-CLICK Spreading procedure 1. Start moving with the tractor. NOTICE Please observe the operating manual of your mineral fertiliser spreader! 2. Start spreader discs. NOTICE While moving, the LEDs light in orange, irrespective of the direction of the movement! 3.
  • Page 24: Error Indication

    In the event of an error, the LED of the affected actuator side will flash red! n CAUTION Material damage caused by short-circuit If the control unit E-CLICK has a short-circuit or interruption, there is the risk that the metering slides cannot be closed. Escaping fertiliser may fall on the road and cause accidents and pollution.
  • Page 25: Close The Metering Slides

    Operation E-CLICK 4.6.3 Close the metering slides NOTICE In the event of an error, the LED of the affected actuator side will flash red! When closing the metering slides, the actuators move against an integrated limit switch; the actuators will be switched off automatically and the LEDs switch from orange to red.
  • Page 26 Operation E-CLICK...
  • Page 27: Terms/Conditions Of Warranty

    Warranty claims are rendered void if RAUCH original spare parts were not used. Therefore, the directions in the operating manual must be observed. In all cases of doubt contact our sales representatives or the factory directly.

Table of Contents