Rauch QUANTRON Complementary Instructions

For axis/mds
Table of Contents

Advertisement

Quick Links

Complementary instructions
Please read carefully
before using the
machine!
Keep for future use
This operator's and assembly manual is
an integral part of the machine. Suppliers
of new and second-hand machines are
required to document in writing that the
operator's and assembly manual was
delivered with the machine and handed
Version 3.52.00
over to the customer.
h
5902662-
-en-1021
Original instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QUANTRON and is the answer not in the manual?

Questions and answers

Summary of Contents for Rauch QUANTRON

  • Page 1 Complementary instructions Please read carefully before using the machine! Keep for future use This operator's and assembly manual is an integral part of the machine. Suppliers of new and second-hand machines are required to document in writing that the operator's and assembly manual was delivered with the machine and handed Version 3.52.00 over to the customer.
  • Page 2 Dear customer, By purchasing the QUANTRON-A control unit for the AXIS and MDS fertilizer spreader, you have shown confidence in our product. Thank you very much! We want to justify this confidence. You have purchased a powerful and reliable machine control unit.
  • Page 3: Table Of Contents

    Metering slide preparation 4 Operation Switching on the machine control unit Navigation within the menus Weighing/Trip counter 4.3.1 Trip counter 4.3.2 Display rest quantity 4.3.3 Zero scales Main menu Fertliser settings in Easy-Mode Fertiliser settings in Expert-Mode QUANTRON-A AXIS/MDS 5902662...
  • Page 4 4.14.1 Entering text 4.14.2 Entering values 4.14.3 Creating screenshots 5 Spreading operation TELIMAT border spreading unit GSE sensor Working with sections 5.3.1 Spreading with reduced sections 5.3.2 Spreading operation with one section and in boundary spreading mode 5902662 QUANTRON-A AXIS/MDS...
  • Page 5 Spreading with the AUTO km/h operating mode Spreading with the MAN km/h operating mode Spreading in the MAN scale operating mode GPS control 6 Alarm messages and possible causes Meaning of the alarm messages Fault/alarm 7 Special equipment 8 Guarantee and warranty QUANTRON-A AXIS/MDS 5902662...
  • Page 6: User Instructions

    Always observe the measures described to prevent this danger. WARNING! Type and source of danger This warning warns of a potentially dangerous situation for personal health. Ignoring these warnings leads to severe injury. ▶ Always observe the measures described to prevent this danger. 5902662 QUANTRON-A AXIS/MDS...
  • Page 7: Notes On Text Descriptions

    The menus list submenus and/or menu items where settings can be made (selection lists, text or number entries, starting a function). The hierarchy and the path to the requested menu item are marked with an > (arrow) between menu and/or menu item(s): QUANTRON-A AXIS/MDS 5902662...
  • Page 8 1. User instructions • System/Test > Test/diagnosis > Voltage means that you can reach the Voltage menu item via the System/Test menu and the Test/diagnosis menu item. ○ The arrow > corresponds to confirmation with the enter key. 5902662 QUANTRON-A AXIS/MDS...
  • Page 9: Layout And Function

    AXIS-M V8 8 section steps Function Spreading depending on forward ● ● ● ● ● ● ● ● speed Mass flow control by measuring ● ● ● ● the torque of the spreading discs Weigh cells ● ● QUANTRON-A AXIS/MDS 5902662...
  • Page 10 AXIS-M VS pro Continuous section adjustment (VariSpread pro) Function Spreading depending on forward speed ● ● ● ● Mass flow control by measuring the torque ● ● ● ● of the spreading discs Weigh cells ● ● 5902662 QUANTRON-A AXIS/MDS...
  • Page 11: Layout Of The Control Unit

    2. Layout and function Layout of the control unit Fig. 1: Control unit QUANTRON-A No. Designation Function Control panel Including membrane keys to operate the device and the display for operating screens Plug connector for connecting the 39-pin plug connector for connecting the machine cable...
  • Page 12: Control Elements

    Display of operating screens T key (TELIMAT) Key to display the TELIMAT settings Start/Stop Start/stop spreading Clear/Reset • Clearing an input in an input field, • Resetting the excess quantity to 100%, • Acknowledgment of alarm messages 5902662 QUANTRON-A AXIS/MDS...
  • Page 13 Function keys F1 to F4 Selection of the functions next to the function keys on the display Weighing/Trip count. • Display of the remaining quantity in the hopper • Trip counter • kg left • Meter counter QUANTRON-A AXIS/MDS 5902662...
  • Page 14: Display

    The most important information concerning the operation of the machine is displayed in the operating screen. 2.4.1 Description of the operating screen The exact representation of the working screen depends on the actual settings selected and on the machine type. Fig. 3: Control unit display – example AXIS-M operating screen 5902662 QUANTRON-A AXIS/MDS...
  • Page 15 Shows the current operating mode Icon TELIMAT This icon appears on the right for AXIS and on the left for MDS if the TELIMAT sensors are installed and the TELIMAT function is enabled (factory setting) or the T key is activated. QUANTRON-A AXIS/MDS 5902662...
  • Page 16 Display of the left section status • See 2.4.2 Display of the metering slide status Left application rate Application rate adjustment (±) in percent adjustment • Display of application rate adjustments • Range of values ± 1...99% possible 5902662 QUANTRON-A AXIS/MDS...
  • Page 17: Display Of The Metering Slide Status

    Display of the metering slide status Fig. 6: Display of the AXIS metering slide status Fig. 7: Display of the MDS metering slide status Spreading operation inactive Machine in spreading operation Section deactivated Section deactivated Section activated Section activated QUANTRON-A AXIS/MDS 5902662...
  • Page 18: Display Of Sections

    Fig. 8: Display of the section status (example with AXIS VariSpread 8) Activated sections with 4 possible spreading The left section is reduced by 2 section width steps steps Further display and setting options are explained in chapter 5.3 Working with sections. 5902662 QUANTRON-A AXIS/MDS...
  • Page 19: Library Of Icons Used

    2. Layout and function Library of icons used The control unit QUANTRON-A displays icons for the individual menus and functions on the screen. 2.5.1 Operating screen icons Icon Meaning Quantity adjustment + (plus) Quantity adjustment - (minus) Quantity adjustment, left + (plus)
  • Page 20: Structural Menu Overview

    In boundary spreading mode: Pressing and holding (> 500 ms) immediately deactivates an entire spreading side. Increase right section (plus) The minimum mass flow is undercut Structural menu overview The Easy/Expert mode is adjusted in the System/Test menu. 5902662 QUANTRON-A AXIS/MDS...
  • Page 21 2. Layout and function Easy Mode QUANTRON-A AXIS/MDS 5902662...
  • Page 22 2. Layout and function Expert Mode 5902662 QUANTRON-A AXIS/MDS...
  • Page 23: Wifi Module

    With the help of the WIFI module (special equipment) and the FertChartApp on a smartphone, you can communicate spreading tables wirelessly to your control unit. Please refer to the manual for the WIFI module. Contact your dealer to install the FertChartApp on your control unit. The WIFI password is quantron. QUANTRON-A AXIS/MDS 5902662...
  • Page 24: Attachment And Installation

    Power supply The tractor supplies the machine control with power via the 3-pin connector (DIN 9680/ISO 12369). Fig. 9: PIN assignment of power socket PIN 1: is not required PIN 3: (31): Ground PIN 2: (15/30): +12 V 5902662 QUANTRON-A AXIS/MDS...
  • Page 25: Forward Speed Signal

    PIN 2: theoretical forward speed (e.g. gearbox, wheel sensor) Connect control unit After having switched on the QUANTRON-A control unit, the machine number is briefly displayed. Note the machine number The QUANTRON-A control unit is factory-calibrated for the fertilizer spreader with which it has been delivered.
  • Page 26: Overview Of Connections To Tractor

    Serial interface RS232, 8-pin plug connector Battery Option: Y-cable (V24 RS232 interface for 3-pin plug connector conforming storage medium) DIN 9680/ISO 12369 Connection for 39-pin machine plug (rear) Option: GPS cable and receiver 7-pin plug connector conforming DIN 9684 5902662 QUANTRON-A AXIS/MDS...
  • Page 27 Wheel sensor Serial interface RS232, 8-pin plug connector Battery Option: Y-cable (V24 RS232 interface for Forward speed sensor storage medium) Option: GPS cable and receiver Connection for 39-pin machine plug (rear) 3-pin plug connector conforming DIN 9680/ISO 12369 QUANTRON-A AXIS/MDS 5902662...
  • Page 28: Overwiew Of Connections To Machine

    DIN 9680/ISO 12369 Option: GPS cable and receiver Battery 3.3.2 Overwiew of connections to machine Fig. 11: Schematic connection diagram of QUANTRON-A – MDS 39-pin machine plug Option (level sensor, left/right) Metering slide actuator, left/right Option (TELIMAT sensor, top/bottom) 5902662...
  • Page 29 3. Attachment and installation AXIS-M variant Q Fig. 12: Schematic connection diagram of QUANTRON-A – AXIS-M variant Q 39-pin machine plug Hopper cover Metering slide rotary drive, left/right Option: SpreadlLight Option (level sensor, left/right) Option TELIMAT sensor and/or GSE sensor,...
  • Page 30 3. Attachment and installation AXIS-M EMC – VariSpread V8 Fig. 13: Schematic connection diagram of QUANTRON-A – AXIS-M EMC V8 39-pin machine plug Option: TELIMAT sensor and/or Weigh cell, left/right (machines with weigh sensor, top/bottom frame only) M EMC sensors (left, right, center)
  • Page 31 3. Attachment and installation AXIS-M EMC – VariSpread VS pro Fig. 14: Schematic connection diagram of QUANTRON-A – AXIS-M EMC VS pro 39-pin machine plug Torque/speed sensor, left/right Weigh cell, left/right (machines with weigh Drop point adjustment, left/right frame only)
  • Page 32: Metering Slide Preparation

    NOTICE! Observe the position of the metering slides of the AXIS fertilizer spreader Operation of the actuators by the control unit QUANTRON-A can cause damage to the metering slides of the machine if the stop levers are incorrectly positioned. ▶...
  • Page 33: Operation

    After a few seconds, the start-up screen of the control unit is displayed. Shortly after, the control unit will display the activation menu for a few seconds. Press the Enter key. The start diagnosis will be displayed for a few seconds. The operating screen then appears. QUANTRON-A AXIS/MDS 5902662...
  • Page 34: Navigation Within The Menus

    Press the Menu key. See 2.3 Control elements The main menu is displayed. The black bar indicates the first sub-menu. Not all parameters are displayed simultaneously in one menu window. The arrow keys enable switching to the next or previous windows. 5902662 QUANTRON-A AXIS/MDS...
  • Page 35 You will return to the previous menu. Press ESC. The previous settings are retained. You will return to the previous menu. Press the Menu key. The operating screen is displayed again. Press the Menu key again to return to the last menu. QUANTRON-A AXIS/MDS 5902662...
  • Page 36: Weighing/Trip Counter

    “0 kg” 4.3.1 Trip counter In this menu, the values of the spreading work carried out can be obtained, the remaining spreading quantity can be observed, and the trip counter can be reset by deleting. 5902662 QUANTRON-A AXIS/MDS...
  • Page 37: Display Rest Quantity

    Display rest quantity In the kg left menu, you can obtain the remaining quantity in the hopper. The menu indicates the possible area (ha) and distance (m) which can still be spread with the remaining fertilizer quantity. QUANTRON-A AXIS/MDS 5902662...
  • Page 38 The remaining quantity from the last spreading process is displayed. Fill the hopper. In the kg field, enter the new total weight of the fertilizer in the hopper. Press the Enter key The unit calculates the values for the possible spread area and distance. 5902662 QUANTRON-A AXIS/MDS...
  • Page 39: Zero Scales

    Press the Enter key. The weighing value for the empty scales is now set to 0 kg. The Weighing trip counter menu is displayed. Tare the scales before each use in order to ensure problem-free calculation of the remaining quantity. QUANTRON-A AXIS/MDS 5902662...
  • Page 40: Main Menu

    Hopper cover Opening/closing the hopper 4.13 Hopper cover cover SpreadLight Activation/deactivation of 4.12 Operating lights operating lights (SpreadLight) System/Test Settings and diagnosis of the 4.10 System/Test machine control unit Info Machine configuration display 4.11 Info 5902662 QUANTRON-A AXIS/MDS...
  • Page 41: Fertliser Settings In Easy-Mode

    Access the menu Main menu > Fertiliser settings. In the M EMC function, the mode is automatically set to expert. Fig. 21: Fertiliser settings menu for AXIS, Easy mode Fig. 22: Fertiliser settings menu for MDS, Easy mode QUANTRON-A AXIS/MDS 5902662...
  • Page 42: Fertiliser Settings In Expert-Mode

    Access the menu Main menu > Fertiliser settings. In the M EMC function, the mode is automatically set to expert. The entries in the Spreading disc and PTO menu item must correspond to the actual settings of your machine. 5902662 QUANTRON-A AXIS/MDS...
  • Page 43 Fig. 23: Fertiliser settings menu for AXIS, Expert mode Fig. 24: Fertiliser settings menu for MDS, Expert mode Fig. 25: Fertiliser settings menu for AXIS/MDS, tabs 3/4 Sub-menu Meaning Description Fertiliser name Fertilizer selected from the fertilizer 4.6.11 Fertilizer charts chart QUANTRON-A AXIS/MDS 5902662...
  • Page 44 Selection with arrow keys, mounted on the mineral fertilizer confirmation with the Enter key spreader Selection list: • • M1XC • Bound. sprd.type Selection with arrow keys, Selection list: confirmation with the Enter key • Limited bd • Full bord. 5902662 QUANTRON-A AXIS/MDS...
  • Page 45: Application Rate

    Control parameters Fertiliser chart Management of fertilizer charts 4.6.11 Fertilizer charts Calculate VariSpread Calculation of values for adjustable 4.6.12 Calculate VariSpread sections 4.6.1 Application rate In this menu, enter the target value for the desired application rate. QUANTRON-A AXIS/MDS 5902662...
  • Page 46: Setting The Working Width

    The M EMC function determines the flow factor specifically for each spreading side. Therefore, a manual input is no longer necessary. The flow factor calculation depends on the operating mode used. For further information about the flow factor, see 4.7.2 AUTO/MAN mode. 5902662 QUANTRON-A AXIS/MDS...
  • Page 47 M EMC function activated, the control unit controls the left and the right metering slide openings separately. Both values are displayed in the operating screen. When the Start/Stop key is pressed, the display updates the indicated flow factor with a slight delay. Subsequently, the display is updated in regular intervals. QUANTRON-A AXIS/MDS 5902662...
  • Page 48: Drop Point

    Enter the determined value in the input field. Press the Enter key. The Fertiliser settings window is displayed with the new drop point. If the drop point is blocked, alarm 17 is displayed; refer to 6.1 Meaning of the alarm messages. 5902662 QUANTRON-A AXIS/MDS...
  • Page 49: Calibration

    If a new fertilizer type is used The calibration must either be conducted with a running PTO at a standstill or while driving over a test section. Remove both spreading discs. Move the drop point to the calibration position (value 0). QUANTRON-A AXIS/MDS 5902662...
  • Page 50 Risk of injury during calibration Rotating machine parts and discharged fertilizer could cause injury. ▶ Before starting the calibration, ensure that all requirements have been met. ▶ Observe the calibration chapter in the operator’s manual for the machine. 5902662 QUANTRON-A AXIS/MDS...
  • Page 51 Any contact with rotating machine parts (drive shaft, hubs) may lead to bruises, abrasions, and crushing injuries. Body parts or objects may be caught or drawn in. ▶ Switch off the tractor engine. ▶ Switch off the hydraulics system and secure it against unauthorized activation. QUANTRON-A AXIS/MDS 5902662...
  • Page 52: Pto Speed

    For optimal Idle measurement, check the correct input in the Fertiliser settings menu. • The entries in the Spreading disc and Normal disc speed or PTO menu items must correspond to the actual settings of your machine. 5902662 QUANTRON-A AXIS/MDS...
  • Page 53: Disc Type

    We recommend reducing the quantity on the boundary spreading side by 20 %. Entering the boundary spreading application rate: Access the menu Fertiliser settings > Bound.quantity (%). Enter the value in the input field and confirm. The Fertiliser settings window is displayed with the new boundary spreading application rate. QUANTRON-A AXIS/MDS 5902662...
  • Page 54: Calculate Optipoint

    Distance from the field border (in meters) at which the Fig. 56 Distance on metering slides open. (measured from field border) Distance from the field border (in meters) at which the Fig. 57 Distance off metering slides close. (measured from field border) 5902662 QUANTRON-A AXIS/MDS...
  • Page 55: Gps Control Info

    You will be able to automatically manage fertilizer charts and transfer them from your control unit. You need a WiFi module (special equipment) and a smartphone to do this. See 2.7 WIFI module You can create up to 30 fertilizer charts in the electronic machine control unit. QUANTRON-A AXIS/MDS 5902662...
  • Page 56 Enter a name for the Fertiliser chart. We recommend naming the fertilizer chart after the fertilizer. Specific fertilizers can thus be assigned to fertilizer charts more easily. Edit the parameters of the fertilizer chart. See 4.6 Fertiliser settings in Expert-Mode. 5902662 QUANTRON-A AXIS/MDS...
  • Page 57: Calculate Varispread

    Calculate VariSpread The VariSpread section assistant automatically calculates the section steps in the background. Your inputs for the working width and the drop point in the first pages of the fertilizer settings provide the basis for this. QUANTRON-A AXIS/MDS 5902662...
  • Page 58: Machine Settings

    GPS terminal. For machines with VariSpread V8, this depends on the GPS terminal. Machine settings In this menu, you can enter settings for the tractor and the machine. Access the menu Machine settings. Fig. 30: Machine settings menu (example) 5902662 QUANTRON-A AXIS/MDS...
  • Page 59: Forward Speed Calibration

    Conduct the calibration on the field. This reduces the influence of the ground characteristics on the calibration result. Determine a 100 m long reference track as precisely as possible. Switch on all-wheel drive. Fill only half of the machine, if possible. QUANTRON-A AXIS/MDS 5902662...
  • Page 60 The displayed values for name, origin, and number of pulses refer to the profile highlighted in red. Press the function key (F1-F4) under the memory location icon. Recalibrating the speed signal You can either overwrite an existing profile or create a profile in an empty memory location. 5902662 QUANTRON-A AXIS/MDS...
  • Page 61 Access the menu item Tractor (km/h) > New calibration > Pulses/100m. The Pulses menu is displayed for manual entry of the pulse count. If the exact pulse count is unknown, start a calibration. QUANTRON-A AXIS/MDS 5902662...
  • Page 62: Auto/Man Mode

    By default, the unit is operated in the automatic mode. You only work in manual mode in the following cases: • If there is no speed signal (radar or wheel sensor not available or defective) • Application of slug pellets or seeds (fine seeds) 5902662 QUANTRON-A AXIS/MDS...
  • Page 63 The AUTO km/h + AUTO kg operating mode continuously adjusts the fertilizer quantity during spreading operation according to the forward speed and the flow behavior of the fertilizer. By doing so, an ideal dosing of the fertilizer can be achieved. QUANTRON-A AXIS/MDS 5902662...
  • Page 64 AUTO km/h: Automatic operating mode To achieve an optimum spreading result, a calibration should be carried out before starting the spreading. Switch on the QUANTRON-A control unit. Access the menu Machine settings > AUTO/MAN mode. Select the AUTO km/h menu item.
  • Page 65 4. Operation MAN scale: Manual operation with a scale value Switch on the QUANTRON-A control unit. Access the menu Machine settings > AUTO/MAN mode. Select the MAN scale menu item. Press the Enter key. The display shows the input window Position of dosing slider.
  • Page 66: Quantity

    In the operating screen, the L%/R% key can only be used to switch between the functions application rate change (L+R) and section management (VariSpread). Press the Enter key. The check mark disappears. You can use the L%/R% key to switch between the 4 different conditions. 5902662 QUANTRON-A AXIS/MDS...
  • Page 67: Fast Emptying

    This prevents the accumulation of humidity in the hopper. Before starting the fast emptying process, care must be taken to ensure that all requirements have been met. Observe the operator’s manual for the mineral fertilizer spreader (discharging residual material). QUANTRON-A AXIS/MDS 5902662...
  • Page 68 Press Start/Stop. The fast emptying process starts. Press Start/Stop when the hopper is empty. Fast emptying is complete. With machines equipped with electrical drop point actuators, the Approach drop point Yes = Start alarm message is activated. 5902662 QUANTRON-A AXIS/MDS...
  • Page 69: Field Data

    Already saved field data files can be selected and processed again. The data already saved in the field data is not overwritten; instead the new values are added. Press the left/right arrow keys to browse forward and back through the pages in the Field data Field data menu. QUANTRON-A AXIS/MDS 5902662...
  • Page 70: Start The Recording

    4. Operation Select the required field data. Press the Enter key. The first page of the current field data is displayed. 4.9.2 Start the recording 5902662 QUANTRON-A AXIS/MDS...
  • Page 71 The Field data menu displays the recording icon for the current field data file. The operating screen displays the recording icon. If a different field data file is opened, the current field data file is stopped. The active field data file cannot be deleted. QUANTRON-A AXIS/MDS 5902662...
  • Page 72: Stopping The Recording

    Recording is finished. 4.9.4 Deleting field data The QUANTRON-A control unit allows deleting of recorded field data. Only the content of the field data will be deleted, the field data name will still be displayed in the name field! 5902662...
  • Page 73: System/Test

    Access the menu Main menu > System/Test. Fig. 39: System/test menu Sub-menu Meaning Description Brightness Display settings The settings can be adjusted with the function keys + and - Language Language setting for menu navigation 4.10.1 Setting the language QUANTRON-A AXIS/MDS 5902662...
  • Page 74: Setting The Language

    Display of values in the selected unit system of units system: • metric • English Service Service settings Password-protected; only accessible for service personnel 4.10.1 Setting the language In the control unit, several languages can be set. 5902662 QUANTRON-A AXIS/MDS...
  • Page 75: Display Configuration

    The languages are listed in several menu windows. The arrow keys enable switching to the next or previous windows. Press the Enter key. The selection is confirmed. The QUANTRON-A control unit restarts automatically. The menus are displayed in the selected language. 4.10.2 Display configuration...
  • Page 76: Setting The Mode

    Press the Enter key. The operating screen is displayed. The respective display field displays the new value. 4.10.3 Setting the mode In the QUANTRON-A control unit, 2 different modes are available. • Easy • Expert In the M EMC function, the mode is automatically set to expert.
  • Page 77: Test/Diagnosis

    Calibration check LIN bus Checking the assemblies registered via Example: LIN bus LIN bus TELIMAT sensor Checking the TELIMAT sensors Sensor brd.spread Checking the sensors for the border Example: GSE sensor spreading unit Hopper cover Checking the actuators QUANTRON-A AXIS/MDS 5902662...
  • Page 78 Function keys for right actuator Signal display Function keys for left actuator The Signal display shows the status of the electrical signals for the left and right side separately. You can open and close the metering slides with the up/down arrows. 5902662 QUANTRON-A AXIS/MDS...
  • Page 79 Example: GSE sensor CAUTION! Risk of injury due to moving machine parts During the tests, machine parts may move automatically. ▶ Before carrying out the tests, ensure that nobody is present in the danger zone of the machine. QUANTRON-A AXIS/MDS 5902662...
  • Page 80: Data Transmission

    Protocol for automatic section control using an external terminal GPS Control VRA VRA: Variable Rate Application Protocol for the automatic transmission of the target application rate TUVR Protocol for automatic section control and application rate change for specific sub-areas with an external Trimble terminal 5902662 QUANTRON-A AXIS/MDS...
  • Page 81: Total Data Counter

    Your system of units has been preset at the factory. However, the system can be changed from metric to English units at any time. Access the menu System/Test. Select the menu Unit. Press the Enter key to switch between imperial and metric. All values of the various menus are converted. QUANTRON-A AXIS/MDS 5902662...
  • Page 82: Info

    In this menu, you can activate the SpreadLight function, to monitor the spreading pattern even in night mode. You can switch the operating lights on and off in the automatic and/or manual mode via the machine control unit. 5902662 QUANTRON-A AXIS/MDS...
  • Page 83 In the manual mode, the operating lights can be switched on and off. Access the menu Main menu > SpreadLight. Put a check mark in the menu item Activate [2]. The operating lights are activated and remain on until you remove the check mark or leave the menu. QUANTRON-A AXIS/MDS 5902662...
  • Page 84: Hopper Cover

    Observe the movements of the hopper cover. Fig. 46: Hopper cover menu Opening process display F2 function key: Stop process F4 function key: Close hopper cover F1 function key: Open hopper cover Static display of the hopper cover 5902662 QUANTRON-A AXIS/MDS...
  • Page 85: Special Functions

    If required, you can stop the movement of the hopper cover by pressing the F2 function key. The hopper cover then remains in the intermediate position until you close or open it completely. 4.14 Special functions 4.14.1 Entering text In some menus, you can enter freely editable text. QUANTRON-A AXIS/MDS 5902662...
  • Page 86 The cursor jumps to the next position. Continue until the entire text is entered. Press the F4/OK function key. The input is confirmed. The control unit saves the text. The display shows the previous menu. Single characters can be overwritten by another character. 5902662 QUANTRON-A AXIS/MDS...
  • Page 87: Entering Values

    The complete input is deleted. Enter new text, if necessary. Press the F4/OK function key. 4.14.2 Entering values In some menus, you can enter numerical values. Fig. 48: Input of numerical value (example: application rate) Input field QUANTRON-A AXIS/MDS 5902662...
  • Page 88: Creating Screenshots

    Creating screenshots With every software update, data will be overwritten. We recommend always storing your settings as screenshots on a USB stick before implementing a software update. Use a USB stick with an illuminated status indicator (LED). 5902662 QUANTRON-A AXIS/MDS...
  • Page 89 Save both pages of the Machine settings menu as screenshots. Store all screenshots on your PC. After the software update, open the screenshots and enter the settings in the QUANTRON-A control unit based on the screenshots. The QUANTRON-A control unit is ready to operate with your settings.
  • Page 90: Spreading Operation

    The boundary spreading key has no function with this option. If the status of the TELIMAT unit cannot be detected for more than 5 seconds, alarm message 14 will be displayed; see 6.1 Meaning of the alarm messages. 5902662 QUANTRON-A AXIS/MDS...
  • Page 91: Gse Sensor

    Function keys for increasing or reducing Function keys for increasing or reducing spreading width on the left spreading width on the right Left section is reduced to 2 steps Each section can be reduced or increased in 4 steps or continuously. QUANTRON-A AXIS/MDS 5902662...
  • Page 92: Spreading Operation With One Section And In Boundary Spreading Mode

    Fig. 51: Operating screen with one section on the left, boundary spreading on the right Display of application rate change in The right spreading side is activated. boundary spreading mode Reduce or increase left section The right spreading side is in boundary Left section adjustable steps spreading mode. (VariSpread 8) 5902662 QUANTRON-A AXIS/MDS...
  • Page 93 Press the Reduce left spreading width function key in order to reduce the section. • If you press the C/100% function key, the full spreading side will be reapplied immediately. • Only for TELIMAT versions without sensor: If you press the T key, boundary spreading is deactivated. QUANTRON-A AXIS/MDS 5902662...
  • Page 94: Spreading With The Automatic Operating Mode (Auto Km/H + Auto Kg)

    Idle measurement is only possible if the actual PTO speed deviates by no more than +/- 10 rpm from the input in the PTO menu. Outside of the range, idle measurement is impossible. Requirements for spreading: • The AUTO km/h + AUTO kg operating mode is active. (See 4.7.2 AUTO/MAN mode) 5902662 QUANTRON-A AXIS/MDS...
  • Page 95 Under certain circumstances, an idle measurement is required in order to record the new reference data before continuing the spreading work. As soon as an idle measurement is required during spreading work, the information screen appears. QUANTRON-A AXIS/MDS 5902662...
  • Page 96: Spreading With The Auto Km/H Operating Mode

    In order to achieve an optimum spreading result in the AUTO km/h operating mode, a calibration should be carried out before starting spreading. Carry out a calibration to determine the flow factor Take the flow factor from the fertilizer chart and manually enter the flow factor. Press Start/Stop. The spreading starts. 5902662 QUANTRON-A AXIS/MDS...
  • Page 97: Spreading With The Man Km/H Operating Mode

    If there is no speed signal (radar or wheel sensor not available or defective) • when spreading slug pellets or fine seeds The MAN scale operating mode is appropriate for slug pellets and fine seeds since the automatic mass flow control cannot be activated due to the low weight reduction. QUANTRON-A AXIS/MDS 5902662...
  • Page 98: Gps Control

    GPS control The QUANTRON-A control unit can be combined with a GPS-compatible device. Various data is exchanged between both devices to automate control. We recommend using our CCI 800 control unit in combination with the QUANTRON-A.
  • Page 99 The OptiPoint function (AXIS only) calculates the optimal switching-on and switching-off point for spreading in headlands on the basis of the settings in the machine control unit; see 4.6.9 Calculate OptiPoint. To use the GPS control functions of the QUANTRON-A control unit, the serial communication must be activated! •...
  • Page 100 If you want to change the switch-on position in the field, you need to adjust the Turn on dist. (m) value. • A lower value for this distance means that the switch-on position is closer to the field border. • A greater value means that the switch-on position is closer to the center of the field. 5902662 QUANTRON-A AXIS/MDS...
  • Page 101 An adjustment of the switch-off distance may lead to insufficient fertilization around the switch-off positions in the field. QUANTRON-A AXIS/MDS 5902662...
  • Page 102: Alarm Messages And Possible Causes

    6. Alarm messages and possible causes Alarm messages and possible causes Meaning of the alarm messages Various alarm messages can be displayed on the QUANTRON-A control unit display. No. Message in display Meaning and possible cause Fault in dosing system, stop !
  • Page 103 The drop point adjustment cannot reach the specified target value. • Blockage • No position feedback • Calibration test 19 Defect by setting drop point The drop point adjustment cannot reach the specified target value. • No position feedback QUANTRON-A AXIS/MDS 5902662...
  • Page 104 47 Left dosing error, hopper empty, outflow • Hopper empty blocked! • Outlet blocked 48 Right dosing error, hopper empty, outflow • Hopper empty blocked! • Outlet blocked 49 Idle meas. implausible. EMC control • Defective sensor deactivated! • Defective transmission 5902662 QUANTRON-A AXIS/MDS...
  • Page 105 This spreading disc type requires conversion of the TELIMAT device. 94 Error at border spreading equip Alarm for the GSE sensor. This error message is displayed if the GSE status is not detected for more than 5 seconds. QUANTRON-A AXIS/MDS 5902662...
  • Page 106: Fault/Alarm

    Fig. 58: Example of an alarm message Acknowledging an alarm message: Rectify the cause of the alarm message. Please observe the operator's manual of the machine and section 6.1 Meaning of the alarm messages. Press the C/100% key. 5902662 QUANTRON-A AXIS/MDS...
  • Page 107: Special Equipment

    7. Special equipment Special equipment Illustration Designation Level sensor Forward speed sensor Y cable RS232 for data exchange (e.g., GPS, N sensor, etc.) System tractor cable set, 12 m QUANTRON-A AXIS/MDS 5902662...
  • Page 108 7. Special equipment Illustration Designation GSP cable and receiver TELIMAT sensor Universal bracket WiFi module 5902662 QUANTRON-A AXIS/MDS...
  • Page 109: Guarantee And Warranty

    • Claims for damage other than to the RAUCH devices will not be accepted. This also means that no liability will be accepted for damage resulting from spreading errors. Unauthorized modifications of the RAUCH devices may result in consequential damage, for which the manufacturer will not accept any liability.

Table of Contents