4
Operation QUANTRON-A
4.10.4

Test/diagnosis

The Test/diagnosis menu enables function monitoring and checking of specific
sensors/actuators.
This menu is for information purposes only.
The list of sensors depends on the equipment of the machine.
Sub-menu
Slide test points
Metering slide
Voltage
Level sensor
Weigh cells
M EMC
Drop point test points Test for approaching the various posi-
Drop point
Linbus
TELIMAT sensor
Hopper cover
74
NOTICE
Meaning
Test for approaching the various posi-
tion points of the sliders.
Approaching the left and right meter-
ing slide
Checking the operating voltage.
Checking the level sensors
Checking the weigh cells.
Checking the sensors for the M EMC
function.
tion points of the drop point.
Approaching the drop point.
Checking the assemblies registered
via LINBUS.
Checking the TELIMAT sensors
Checking the actuators.
Description
Checking the cali-
bration
Page 75
Checking the cali-
bration