Rauch QUANTRON-A Instruction Manual

Rauch QUANTRON-A Instruction Manual

For axis-m and mds
Hide thumbs Also See for QUANTRON-A:
Table of Contents

Advertisement

Quick Links

INSTRUCTION MANUAL
Please read carefully
before using the ma-
chine.
Keep for future reference.
This instruction manual/assembly in-
struction is to be considered as part of
the machine. Suppliers of new and sec-
ond-hand machines are required to
document in writing that the instruc-
tion manual/assembly instruction was
Version 3.30.00
delivered with the machine and hand-
ed over to the customer.
Original instructions
c
5902662-
-en-0120

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QUANTRON-A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rauch QUANTRON-A

  • Page 1 INSTRUCTION MANUAL Please read carefully before using the ma- chine. Keep for future reference. This instruction manual/assembly in- struction is to be considered as part of the machine. Suppliers of new and sec- ond-hand machines are required to document in writing that the instruc- tion manual/assembly instruction was Version 3.30.00 delivered with the machine and hand-...
  • Page 2: Technical Improvements

    Note the serial number of the control unit and the machine. The Control unit QUANTRON-A has been calibrated at the factory for the fertiliser spreader with which it was supplied. It cannot be connected to another fertiliser spreader without additional calibration.
  • Page 3: Table Of Contents

    Preparing the metering slider......... . 30 Operation QUANTRON-A Switching on the control unit .
  • Page 4 Table of Contents Fertiliser settings in expert mode ........41 4.6.1 Application rate .
  • Page 5 Table of Contents Spreading operation using the QUANTRON-A control unit TELIMAT ............91 Working with sections (AXIS only).
  • Page 6 Table of Contents...
  • Page 7: User Instructions

    User instructions About this operating manual This operating manual is an integral part of the control unit QUANTRON-A. The operating manual contains important information for safe, appropriate and economic use and maintenance of the control unit. Compliance with its stipula- tions helps to avoid risks, reduce repair costs and downtimes and increase the reliability and service life of the machine.
  • Page 8 User instructions Warning severity level The degree of danger is indicated by the signal word. The levels are classified as follows: n DANGER Type and source of danger This warning warns of a danger posing an immediate threat to the health and life of persons.
  • Page 9: Instructions And Procedures

    User instructions 1.2.2 Instructions and procedures Steps that the operator must carry out are shown as a numbered list. 1. Instruction for action step 1 2. Instruction for action step 2 Instructions involving only one step are not numbered. The same applies for action steps that do not have a specific sequence.
  • Page 10 User instructions...
  • Page 11: Layout And Function

    Layout and function Layout and function Overview of the supported versions NOTICE Some models are not available in all countries. 2.1.1 Function/options Spreading depending on forward speed MDS 8.2 Q  MDS 14.2 Q  MDS 18.2 Q  MDS 20.2 Q ...
  • Page 12: Axis-M

    Layout and function 2.1.2 AXIS-M NOTICE Some models are not available in all countries. AXIS-M V8 8 section width steps (VariSpread Dynamic) Function/options Spreading depending on         forward speed Mass flow control by measuring the torque of ...
  • Page 13: Layout Of The Control Unit - Overview

    Layout and function Layout of the control unit - overview Figure 2.1: QUANTRON-A control unit Description Function Control panel Including membrane keys used to operate the device and the display for operating screens. Machine cable plug 39-pin plug connector for connecting the machine connector cable to sensors and servomotors (SpeedServos).
  • Page 14: Control Elements

    Layout and function Control elements The unit is operated with 17 membrane keys (13 permanently defined and 4 freely configurable membrane keys). Figure 2.2: Control panel at the front of the unit Description Function ON/OFF Switches the device on/off Display Display of operating screens T key (TELIMAT) Key for displaying the TELIMAT position...
  • Page 15 Layout and function Description Function Preselected section Toggle key for alternating between four states. width setting Pre-selection of section widths for changing the  quantity. Page 65 L: Left R: Right or L+R: Left + Right AXIS only: Management of the section widths ...
  • Page 16: Display

    Layout and function Display The display shows the current status information and the selection and input options for the control unit. The most important information on the operation of the fertiliser spreader is displayed on the operating screen. 2.4.1 Description of the operating screen NOTICE The exact display of the operating screen depends on the currently selected settings, see chapter...
  • Page 17 Layout and function Figure 2.5: Control unit display (MDS operating screen example)
  • Page 18 Layout and function The symbols and displays in the example have the following meanings: No. Symbol/Display Meaning (in the example shown) Metering slider Current opening position of the left metering slider. scale opening left Operating mode Shows the current operating mode. TELIMAT symbol This symbol appears on the right for AXIS and on the left for MDS if the TELIMAT sensors are installed...
  • Page 19: Display Of The Metering Slider Statuses

    Layout and function 2.4.2 Display of the metering slider statuses Figure 2.6: AXIS metering slider status display Figure 2.7: MDS metering slider status display [A] Spreading operation inactive (STOP) [1] Section width deactivated [2] Section width activated [B] Machine in spreading operation (START) [3] Section width deactivated [4] Section width activated...
  • Page 20: Section Width Display (Axis Only)

    Layout and function 2.4.3 Section width display (AXIS only) Figure 2.8: Display of the section width statuses (example with VariSpread 8) [1] Activated section widths with four possible spreading width steps [2] The left section width is reduced by two section width steps Further display and setting options are explained in the chapter 5.2: Working with sections (AXIS only), page...
  • Page 21: Library Of Symbols Used

    Layout and function Library of symbols used The screen of the QUANTRON-A control unit displays symbols for functions. Symbol Meaning Quantity change + (plus) Quantity change - (minus) Quantity change, left + (plus) Quantity change, left - (minus) Quantity change, right + (plus)
  • Page 22 Layout and function Symbol Meaning Reduce right section width (minus) Increase right section width (plus) Reduce left section width (minus) Increase left section width (plus)
  • Page 23: Structural Overview Of Easy Mode Menu

    Layout and function Structural overview of Easy Mode menu Setting the mode is described in section 4.10.3: Mode, page...
  • Page 24: Structural Overview Of Expert Mode Menu

    Layout and function Structural overview of Expert Mode menu Setting the mode is described in section 4.10.3: Mode, page...
  • Page 25: Wlan Module

    Layout and function WLAN module With the help of the WLAN module (special equipment) and the FertChartApp on a smart phone, you can wirelessly transfer spreading charts to your control unit. Observe the installation instructions for the WLAN module. Contact your dealer to install the FertChartApp on your control unit.
  • Page 26 Layout and function...
  • Page 27: Attachment And Installation

    Attachment and installation Attachment and installation Requirements for the tractor Before installing the control unit, check to make sure your tractor meets the following requirements: A minimum voltage of 11 V is essential at all times, even if multiple loads are ...
  • Page 28: 7-Pin Plug Connector

    Attachment and installation 3.2.2 7-pin plug connector The control unit receives the pulses for the current forward speed via the 7-pin plug connector 9684-1/ISO 11786). For this purpose, the 7-pin to 8-pin cable (accessory) is connected to the forward speed sensor at the plug connector. [1] PIN 1: actual forward speed (radar) [2] PIN 2: theoretical forward speed (e.
  • Page 29: Connecting The Control Unit

    Attachment and installation Connecting the control unit NOTICE After the QUANTRON-A control unit has been switched on, the display shows the machine number for a short time. NOTICE Note the machine number The QUANTRON-A control unit is factory-calibrated for the fertiliser spreader with which it has been delivered.
  • Page 30: Connection Overviews On The Tractor

    Connection overviews on the tractor Standard km/h Figure 3.3: Schematic connection diagram QUANTRON-A (standard) [1] RS232 serial interface, 8-pin plug connector [2] Option: Y-cable (V24 RS232 interface for storage medium) [3] Connection for 39-pin machine plug (rear) [4] 7-pin plug connector according to DIN 9684...
  • Page 31 Attachment and installation Wheel sensor km/h Figure 3.4: Schematic connection diagram QUANTRON-A (wheel sensor) [1] RS232 serial interface, 8-pin plug connector [2] Option: Y-cable (V24 RS232 interface for storage medium) [3] Connection for 39-pin machine plug (rear) [4] 3-pin plug connector according to DIN 9680/ISO 12369...
  • Page 32 [3] Connection for 39-pin machine plug (rear) [4] 3-pin plug connector according to DIN 9680/ISO 12369 [5] Battery [6] Forward speed sensor [7] 7-pin plug connector according to DIN 9684 [8] Option: QUANTRON-A power supply via ignition lock [9] Option: GPS cable and receiver...
  • Page 33: Connection Diagrams At The Machine

    Attachment and installation 3.3.2 Connection diagrams at the machine Figure 3.6: Schematic connection diagram QUANTRON-A [1] 39-pin machine plug [2] Metering slider actuator left/right [3] Option (level sensor left/right) [4] Option (TELIMAT sensor top/bottom) AXIS-M Q Figure 3.7: Schematic connection diagram QUANTRON-A...
  • Page 34 Attachment and installation AXIS-M EMC V8 Figure 3.8: Schematic connection diagram QUANTRON-A [1] 39-pin machine plug [2] Weigh cell left/right (only machines with weighing frame) [3] Metering slider rotary drive, left/right [4] Option: Filling level sensor left/right [5] Option: TELIMAT sensor top/bottom...
  • Page 35 Attachment and installation AXIS-M EMC VS pro Figure 3.9: Schematic connection diagram QUANTRON-A [1] 39-pin machine plug [2] Weigh cell left/right (only machines with weighing frame) [3] Metering slider rotary drive, left/right [4] Option: filling level sensor left/right [5] Option: TELIMAT sensor top/bottom...
  • Page 36: Preparing The Metering Slider

    CAUTION Observe the position of the metering slides at the AXIS fertiliser spreader Operating the actuators with the QUANTRON-A can cause damage to the machine's metering slides if the stop levers are positioned incorrectly.  Always clamp the stop levers at the maximum scale position.
  • Page 37: Operation Quantron-A

     the tractor (for an example, see chapter 3.3: Connecting the control unit, page 23). A minimum voltage of 11 V is guaranteed.  NOTICE The operating manual describes the functions of the QUANTRON-A control unit from software version 3.30.00.
  • Page 38 Operation QUANTRON-A Switching on the unit: 1. Press the ON/OFF key [1].  After a few seconds, the start-up screen of the control unit appears.  Shortly afterwards, the control unit displays the Activation menu for a few seconds. 2. Press the enter key.
  • Page 39: Menu Navigation

    Operation QUANTRON-A Menu navigation NOTICE Important notes regarding the display and navigation between menus are pro- vided in chapter 1.2.5: Menu hierarchy, keys and navigation, page Accessing the main menu Press the Menu key. See 2.3: Control elements, page ...
  • Page 40: Weighing - Trip Counter

    Operation QUANTRON-A Weighing - Trip counter This menu provides values regarding the spreading work carried out as well as functions for weighing operation. Press the kg key on the control unit.   The Weighing - Trip counter menu appears.
  • Page 41: Trip Counter

    Operation QUANTRON-A 4.3.1 Trip counter This menu provides the following values: kg spread (kg) ha spread (ha) m spread (m) Figure 4.3: Trip counter menu [1] Display of the quantity spread since the last reset [2] Display of the area spread since the last reset...
  • Page 42: Displaying The Remaining Quantity

    Operation QUANTRON-A 4.3.2 Displaying the remaining quantity In the Rest (kg, ha, m) menu, you can check or enter the remaining quantity in the hopper. The menu shows the possible area (ha) and distance (m) which can still be spread with the remaining fertiliser quantity. Both displays are calculated based...
  • Page 43: Zeroing The Scales (Axis With Weigh Cells Only)

     This returns you to the operating screen. Calling up the remaining quantity during spreading: During spreading, the remaining quantity is continuously recalculated and displayed. See chapter 5: Spreading operation using the QUANTRON-A control unit, page 4.3.3 Zeroing the scales (AXIS with weigh cells only) In this menu, the weight for the empty hopper is to be set to 0 kg.
  • Page 44: Main Menu

    Operation QUANTRON-A Main menu Figure 4.5: QUANTRON-A main menu The main menu displays the following sub-menus. NOTICE Not all parameters are displayed simultaneously in one menu window. With the arrow keys you can jump to the adjacent window. Sub-menu Meaning...
  • Page 45: Fertiliser Settings In Easy Mode

    Operation QUANTRON-A Fertiliser settings in Easy mode The mode settings are described in section 4.10.3: Mode, page In this menu, you can make the fertiliser and spreading operation settings. Open the menu Main menu > Fertiliser settings.  NOTICE For the M EMC function, the mode is automatically set to Expert.
  • Page 46 Operation QUANTRON-A Sub-menu Meaning/possible values Description Fertiliser name Selected fertiliser. Appl. rate (kg/ha) Target value entry for the application rate Page 44 in kg/ha. Working width (m) Determination of the working width to be Page 44 spread. Flow factor Enter the flow factor of the fertiliser used...
  • Page 47: Fertiliser Settings In Expert Mode

    Operation QUANTRON-A Fertiliser settings in expert mode The mode settings are described in section 4.10.3: Mode, page NOTICE For the M EMC function, the mode is automatically set to Expert. In this menu, you can make the fertiliser and spreading operation settings.
  • Page 48 Operation QUANTRON-A Figure 4.10: Fertiliser settings menu, page 3 (AXIS/MDS) The main menu displays the following sub-menus. Sub-menu Meaning/possible values Description Fertiliser name Fertiliser selected from the fertiliser chart. Page 55 Appl. rate (kg/ha) Target value entry for the application rate Page 44 in kg/ha.
  • Page 49 Operation QUANTRON-A Sub-menu Meaning/possible values Description Spreading discs Selection list: Select with arrow keys and  confirm with M1XC  enter key  Default setting: 540 rpm Page 52 Boundary spread- Selection list: Select with ing type arrow keys and Border ...
  • Page 50: Application Rate

    Operation QUANTRON-A 4.6.1 Application rate In this menu, you can enter the target value for the desired application rate. Entering the application rate: 1. Open the menu Fertiliser settings > Appl. rate (kg/ha).  The display shows the currently active application rate.
  • Page 51: Flow Factor

    NOTICE Via the Calibration menu, the flow factor can be determined and entered using the QUANTRON-A control unit. See chapter 4.6.6: Calibration test, page 49 The M EMC function determines the flow factor specifically for each spreading side.
  • Page 52 Operation QUANTRON-A Minimum factor The machine control system automatically sets the minimum factor to one of the following values, according to the flow factor value entered: The minimum factor is 0.2 if the input value is smaller than 0.5. ...
  • Page 53: Drop Point

    Operation QUANTRON-A 4.6.4 Drop point MDS, AXIS-M Q V8 NOTICE Entering the drop point is merely of informative character and does not affect the settings of the mineral fertiliser spreader for machines of variant Q. In this menu, you can enter the drop point for informational purposes.
  • Page 54: Telimat Quantity

    Operation QUANTRON-A 4.6.5 TELIMAT Quantity In this menu, the TELIMAT quantity reduction can be set (in percent). This setting is used for the activation of the border spreading function via the TELIMAT sensor or the T key. NOTICE We recommend reducing the quantity on the border spreading side by 20%.
  • Page 55: Calibration Test

    Operation QUANTRON-A 4.6.6 Calibration test NOTICE The Calibration menu is locked for the M EMC function and in AUTO km/h + AUTO kg operating mode. This menu item is inactive. In this menu, the flow factor is determined based on a calibration test and saved in the control unit.
  • Page 56 Operation QUANTRON-A Conducting the calibration test: n WARNING Risk of injury during the calibration test Rotating machine components and ejected fertiliser may cause injury.  Before starting the calibration test, make sure all requirements are met.  Observe the Calibration chapter in the operating manual of the machine.
  • Page 57 Operation QUANTRON-A Recalculating the flow factor n WARNING Risk of injury due to rotating machine components Contact with rotating machine components (universal drive shaft, hubs) may cause bruises, abrasions and crushing injuries. Body parts or objects may be caught or pulled in.
  • Page 58: Spreading Disc Type

    Operation QUANTRON-A 4.6.7 Spreading disc type NOTICE For an optimal idle measurement you must check that the entries in the Fertiliser settings menu are correct. The Spreading disc and PTO speed menu entries must match the actual  settings of your machine.
  • Page 59: Calculate Optipoint (Axis Only)

    Operation QUANTRON-A 4.6.9 Calculate OptiPoint (AXIS only) In the Calculate OptiPoint menu, enter the parameters for calculating the optimal switch-on/switch-off distances in the headland. For an exact calculation, it is very important to enter the distance factor of the fertiliser used.
  • Page 60: Gps Control Info

    Operation QUANTRON-A NOTICE You can manually adjust the parameter values on this page. See chapter 5.7: GPS Control, page 100. Changing the values 6. Highlight the desired entry. 7. Press the enter key. 8. Enter the new values. 9. Press the enter key.
  • Page 61: Fertiliser Chart

    Operation QUANTRON-A 4.6.11 Fertiliser chart In this menu, you can create and manage your own fertiliser charts. NOTICE The selection of a fertiliser chart has an effect on the fertiliser settings, the control unit and the mineral fertiliser spreader. The set application rate is overwritten by the stored value from the fertiliser chart.
  • Page 62 Operation QUANTRON-A NOTICE We recommend giving the fertiliser chart the name of the fertiliser. In this way, specific fertilisers can be assigned to fertiliser charts more easily. 9. Editing the parameters of the fertiliser chart. See chapter 4.6: Fertiliser settings in expert mode, page Selecting a fertiliser chart: 1.
  • Page 63: Calculate Varispread

    Operation QUANTRON-A 4.6.12 Calculate VariSpread The VariSpread section width wizard automatically calculates the section width steps in the background. This is based on your entries for the working width and the drop point on the first pages of the Fertilizer settings menu.
  • Page 64: Machine Settings

    Operation QUANTRON-A Machine settings NOTICE The Machine settings menu is different for the AXIS and MDS fertiliser spreaders. The tractor and machine settings can be configured in this menu. Open the Machine settings menu.  Figure 4.15: Machine settings (example) menu...
  • Page 65: Forward Speed Calibration

    Fill only half of the machine, if possible.  Calling up the speed settings: In the QUANTRON-A control unit, you can save up to four different profiles for the type and number of pulses. You can assign names to these profiles (e.g. tractor name).
  • Page 66 Operation QUANTRON-A Recalibrating the speed signal: You can either overwrite an existing profile or create a profile at an empty memory location. 1. Highlight the desired memory location in the Tractor (km/h) menu using the function key below. 2. Highlight the New calibration field.
  • Page 67 Operation QUANTRON-A Subsequently, the number of pulses of the forward speed signal has to be defined. If the exact number of pulses is known, you can enter it directly: 8. Call up the Tractor (km/h) > New calibration > Pulses/100 m menu entry.
  • Page 68: Auto/Man Mode

    Forward speed adjustment for Page 98 manual mode Selecting the operating mode 1. Switch on the QUANTRON-A control unit. 2. Open the menu Machine settings > AUTO/MAN mode. 3. Select the desired menu item. 4. Press the enter key. 5. Follow the instructions on the screen.
  • Page 69 In order to achieve optimum spreading results, you should conduct a calibration test before beginning the spreading work. 1. Switch on the QUANTRON-A control unit. 2. Open the menu Machine settings > AUTO/MAN mode. 3. Highlight the AUTO km/h menu entry 4.
  • Page 70 Operation QUANTRON-A MAN scale: manual operation with scale value 1. Open the menu Machine settings > AUTO/MAN mode. 2. Highlight the MAN scale menu entry.  The display shows the Metering slider opening menu. 3. Enter the scale value for the metering slider opening.
  • Page 71: Application Rate

    Operation QUANTRON-A 4.7.3 +/- application rate In this menu, you can specify the percentage of quantity change for standard spreading. The base (100%) is the preset value for the opening of the metering slider. NOTICE During operation, you can use the F2/F3 function keys to change the application rate by the factor of +/- application rate at any time.
  • Page 72: Easy Toggle (Axis Only)

    Operation QUANTRON-A 4.7.5 Easy Toggle (AXIS only) Here you can limit the toggle function of the L% / R% key to two states of the func- tion keys F1 to F4. By doing so, you can avoid unnecessary toggling action on the operating screen.
  • Page 73: Fast Emptying

    Fast emptying menu. Before storing the machine, we recommend completely opening the metering sliders by means of fast emptying and switching off the QUANTRON-A in this state. This prevents accumulation of moisture in the hopper.
  • Page 74 Operation QUANTRON-A 2. Press the function key to select the section width for which the fast emptying function is to be carried out.  The selected section width is shown as a symbol on the display. 3. Press the Start/Stop key.
  • Page 75: Field Data

    Operation QUANTRON-A Field data In this menu, you can create and manage up to 200 field files. Open the menu Main menu > Field data.  Figure 4.21: Field data menu [1] Page number display [2] Display of filled field file...
  • Page 76: Starting Recording

    Operation QUANTRON-A 4.9.2 Starting recording Figure 4.22: Display of the current field file [1] Display of the page number [2] Name field of the field file [3] Value fields [4] Display of the start time/date [5] Display of the stop time/date...
  • Page 77 Operation QUANTRON-A 3. Press the F1 function key under the start symbol.  The recording starts.  The Field data menu displays the recording symbol for the current field file.  The operating screen displays the recording symbol. NOTICE If a different field file is opened, the current field file is stopped. The active field data file cannot be deleted.
  • Page 78: Stopping Recording

     The recording is stopped. 4.9.4 Deleting field files The QUANTRON-A control unit facilitates the deletion of recorded field files. NOTICE Only the content of the field files is deleted. The field file name is still displayed in the name field! Deleting a field file 1.
  • Page 79: System/Test

    Operation QUANTRON-A 4.10 System/Test Use this menu for the system and test settings of the control unit. Call up the Main menu > System/Test menu.  Figure 4.24: System/Test menu Sub-menu Meaning Description Brightness Display settings. Settings can be adjusted using the function keys + or -.
  • Page 80 Operation QUANTRON-A Sub-menu Meaning Description Time Setting the current time. Select and modify the setting with the arrow keys and confirm with the enter key Data Menu for data exchange and Page 81 transmission serial protocols Total data Display of the entire...
  • Page 81: Setting The Language

    Operation QUANTRON-A 4.10.1 Setting the language In the QUANTRON-A control unit, several languages can be set. The language for your country is pre-set at the factory. 1. Open the menu System/Test > Language.  The display shows the first of four pages.
  • Page 82: Display Configuration

    Operation QUANTRON-A 4.10.2 Display configuration The display fields in the operating screen of the control unit can be configured as desired. You can assign the three display fields with the following values if desired: Forward speed  Flow factor (FF) ...
  • Page 83: Mode

    Operation QUANTRON-A 4.10.3 Mode In the QUANTRON-A control unit, two different modes are possible: Easy mode or Expert mode. NOTICE With the M EMC function, the mode is automatically set to Expert. In Easy mode, only the parameters of the fertiliser settings which are neces- ...
  • Page 84: Test/Diagnosis

    Operation QUANTRON-A 4.10.4 Test/diagnosis In the Test/diagnosis menu, you can monitor and test the function of some sensors/actuators. NOTICE This menu is for information purposes only. The list of sensors depends on the equipment of the machine. Sub-menu Meaning Description...
  • Page 85 Operation QUANTRON-A Metering slider example n CAUTION Risk of injury caused by moving machine parts. Machine parts can move automatically during the tests.  Ensure that nobody is present in the area of the machine before carrying out the tests.
  • Page 86 Operation QUANTRON-A Example: Linbus 1. Open the menu System/Test > Test/diagnosis. 2. Select the Linbus menu item. 3. Press the enter key.  The actuator/sensor status is displayed. Figure 4.28: Test/diagnosis; example: Linbus [1] Status display [2] Start self-test [3] Connected actuators...
  • Page 87: Data Transmission

    Operation QUANTRON-A 4.10.5 Data transmission Data transmission is carried out using various data protocols. Sub-menu Meaning Automatic field documentation; transmission of field data to a PDA and/or Pocket PC via Bluetooth LH5000 Serial communication e.g. spreading using application maps GPS Control...
  • Page 88: Changing The Units Of Measurement

    Operation QUANTRON-A 4.10.7 Changing the units of measurement The units of measurement have been preset at the factory. However, you can switch from metric to imperial values and vice versa at any time. 1. Open the System/Test menu. 2. Select the Units menu.
  • Page 89: Spreadlight Operating Light (Axis Only, Special Equipment)

    Operation QUANTRON-A 4.12 SpreadLight operating light (AXIS only, special equipment) In this menu, you can activate the SpreadLight function and monitor the spreading pattern even in night mode. You switch the operating lights on and off via the machine control unit in automatic or manual mode.
  • Page 90: Hopper Cover (Axis Only, Special Equipment)

    Operation QUANTRON-A 4.13 Hopper cover (AXIS only, special equipment) n WARNING Danger of crushing and shearing due to components operated by an external force The hopper cover moves without any previous warning and can injure people.  Ensure that nobody is present in the danger zone.
  • Page 91 Operation QUANTRON-A n CAUTION Material damage due to insufficient clearance Opening and closing the hopper cover requires a sufficient clear- ance above the hopper. If the clearance is too small, the hopper cover may tear. The frame of the hopper cover can break and the hopper cover can cause damage to the surroundings.
  • Page 92: Special Functions

    Operation QUANTRON-A 4.14 Special functions 4.14.1 Text input Freely editable text can be entered in some menus. Figure 4.31: Text input menu [1] Input field [2] Character field, display of available characters (language dependent) [3] Function keys for navigation in the input field Entering text: 1.
  • Page 93 Operation QUANTRON-A Overwriting characters: A single character can be overwritten by another character. 1. Use the function keys to move the cursor to the position of the character to be deleted first in the input field. 2. Use the arrow keys to highlight the character to be written in the character field.
  • Page 94: Input Of Values Using The Cursor Keys

    Operation QUANTRON-A 4.14.2 Input of values using the cursor keys In some menus, numerical values can be entered. Figure 4.32: Numerical value input (application rate example) [1] Input field Precondition: You are already in the menu in which you can enter numerical values.
  • Page 95: Creating Screen Shots

    9. Store all screen shots on your PC. 10. After the software update, open the screen shots and enter the settings in the Control unit QUANTRON-A based on the screen shots.  The Control unit QUANTRON-A is ready to operate with your settings.
  • Page 96 Operation QUANTRON-A...
  • Page 97: Spreading Operation Using The Quantron-A Control Unit

    Spreading operation using the QUANTRON-A control unit Spreading operation using the QUANTRON-A control unit The QUANTRON-A control unit supports you in setting the machine before you start work. During spreading, control unit functions are also active in the back- ground. The quality of the fertiliser spreading can be monitored using them.
  • Page 98: Working With Sections (Axis Only)

    Spreading operation using the QUANTRON-A control unit Working with sections (AXIS only) 5.2.1 Spreading with reduced section widths Spreading can be done with section widths on one or both sides, in order to adapt the overall spreading width to the field requirements. Each spreading side can be adjusted in four steps (VariSpread 8) or gradually (VariSpread pro).
  • Page 99: (Axis-M V8)

    Spreading operation using the QUANTRON-A control unit 5.2.2 Spreading operation with one section width in border spreading mode (AXIS-M V8) During the spreading operation, the section widths can be changed gradually and border spreading activated. The figure below shows the operating screen with activated border spreading and selected section widths.
  • Page 100: Spreading Operation With One Section Width In Border Spreading Mode

    Spreading operation using the QUANTRON-A control unit 5.2.3 Spreading operation with one section width in border spreading mode (AXIS-M VS pro) During spreading, you can change the section widths step-by-step and deactivate border spreading. The figure below shows the working screen with activated limited border spreading and an activated section width.
  • Page 101: Spreading With Automatic Operating Mode (Auto Km/H + Auto Kg, Axis Only)

    Spreading operation using the QUANTRON-A control unit Spreading with automatic operating mode (AUTO km/h + AUTO kg, AXIS only) Mass flow control with the M EMC function The mass flow is measured separately on both spreading disc sides. Thus deviations to the specified application rate can be immediately corrected.
  • Page 102 Spreading operation using the QUANTRON-A control unit 7. Wait until the progress bar has entirely run through.  Idle measurement is finished  Idle time is reset to 20 min. 8. Press the Start/Stop key.  The spreading starts. As long as the PTO is operating, a new idle measurement will automatically start after the expiration of the idle time every 20 minutes.
  • Page 103: Spreading In Auto Km/H Operating Mode

    Spreading operation using the QUANTRON-A control unit Spreading in AUTO km/h operating mode In AUTO km/h operating mode, the control unit automatically controls the actuator depending on the speed signal. 1. Make the fertiliser settings: Application rate (kg/ha)  Working width (m) ...
  • Page 104: Spreading In Man Km/H Operating Mode

    Spreading operation using the QUANTRON-A control unit Spreading in MAN km/h operating mode You are working in MAN km/h operating mode if there is no speed signal. 1. Switch on the QUANTRON-A control unit. 2. Open the menu Machine settings > AUTO/MAN mode.
  • Page 105: Spreading In Man Scale Operating Mode

    Spreading operation using the QUANTRON-A control unit Spreading in MAN scale operating mode In MAN scale operating mode, you can manually change the metering slider opening during spreading. You are working in manual mode only: If there is no speed signal (radar or wheel sensor not available or defective), ...
  • Page 106: Gps Control

    Spreading operation using the QUANTRON-A control unit GPS Control The QUANTRON-A control unit can be combined with GPS-compatible devices. Various data are exchanged between both devices to automate the control. NOTICE We recommend using our CCI 800 control unit in combination with the QUANTRON-A.
  • Page 107 Spreading operation using the QUANTRON-A control unit Figure 5.6: Spreading operation display on the operating screen with GPS Control Switch-on distance (m) Switch-on distance refers to the switch-on distance (Figure 5.7 [A]) relating to the field border (Figure 5.7 [C]). At this position in the field, the metering slides start to open.
  • Page 108 Spreading operation using the QUANTRON-A control unit Switch-off distance (m) Switch-off distance refers to the switch-off distance (Figure 5.8 [B]) relating to the field border (Figure 5.8 [C]). At this position in the field, the metering slides start to close.
  • Page 109: Alarm Messages And Possible Causes

    Alarm messages and possible causes Alarm messages and possible causes Various alarm messages can be displayed on the QUANTRON-A control unit. Meaning of alarm messages No. Message on display Meaning Possible cause  Fault in dosing system. Stop! The actuator for the metering system cannot reach the target value it is to be moved to.
  • Page 110 Alarm messages and possible causes No. Message on display Meaning Possible cause  Flow factor Reference to the value range of the flow Min. setting = 0.40 factor. Max. setting = 1.90 Entered value is not permitted.  Transmission fault. No An error has occurred during data RS232 connection transmission to the control unit.
  • Page 111 Alarm messages and possible causes No. Message on display Meaning Possible cause  Externally controlled parts Parts may move unexpectedly when the may move. Risk of injury machine control unit is switched on. through squeezing and Follow the displayed instructions only if ...
  • Page 112: Clearing A Fault/Alarm

    Alarm messages and possible causes Clearing a fault/alarm 6.2.1 Acknowledging an alarm message Alarm messages are highlighted on the display and indicated by a warning symbol. Figure 6.1: Alarm message (metering device example) Acknowledging an alarm message: 1. Rectify the cause of the alarm message. See the operating manual for the fertiliser spreader and section 6.1: Meaning of alarm messages, page 103.
  • Page 113: Special Equipment

    Special equipment Special equipment No. Illustration Designation Level sensor for AXIS/MDS Forward speed sensor for QUANTRON-A Y cable RS232 for data exchange (e.g. GPS, N sensor etc.) System tractor cable set for QUANTRON-A 12 m AXIS...
  • Page 114 Special equipment No. Illustration Designation GPS cable and receiver TELIMAT sensor AXIS Universal holder for QUANTRON-A WLAN module...
  • Page 115: Index

    Index Index Application rate Fast emptying 12, 44 Fertiliser Fertiliser chart Border spreading 43, 93 Create 56 Border spreading mode Fertiliser settings 31, 38 Brightness Application rate 44 Border spreading 43 Calibration 49–51 Calculate Composition 43 VariSpread 57 Fertilisation 43 Calibration Fertiliser chart 43, 56 Calibration test...
  • Page 116 Index Metering slider 12, 53 Test points 78–80 Mode Arrow keys 9 Enter 9 Easy 17 ESC 9 Expert 18 Function key 9 Mounting height kg key 9 Menu 9, 33 ON/OFF 8 Navigation T key 8 Keys 9 kg key Symbols 15 Normal fertilisation Language...
  • Page 117 Index Spreading disc Test/diagnosis 73, 78 Drop point 78 Spreading mode Level sensor 78 AUTO km/h + AUTO kg 95 Metering slider 78–80 M EMC function 95 TELIMAT 78 Spreading operation 91–102 Test points 78 AUTO km/h 97 Voltage 78 Border spreading 93–94 Weigh cells 78 MAN km/h 98...
  • Page 118 Index...
  • Page 119: Terms/Conditions Of Warranty

    Warranty claims are rendered void if RAUCH original spare parts were not used. Therefore, the directions in the operating manual must be observed. In all cases of doubt contact our sales representatives or the factory directly.