Vari Lite VLX3 User Manual page 94

Wash luminaires
Table of Contents

Advertisement

VARI
LITE - VLX3 W
PHOTOMETRIC
OPERATIONAL
Power Requirements
Standard AC power distribution from 100-240 VAC, 50/60 Hz. The fixture requires up to 7A depending
on the AC supply voltage.
Operational Temperature
-20° to 122°F (-29° to 50°C)
Cooling
Variable forced air cooling.
Control
Completely compatible with a wide variety of DMX512 lighting control consoles. Channel Count
depends on mode selected by user. 5-pin in and thru DMX.
Weight
44 lbs. (20.0 kg)
NOTE: Vari-Lite reserves the right to change details of design, materials and finishes. Specifications are subject
to change without notice. VARI
78
L
U
'
ASH
UMINAIRE
SER
LED
Zoom
Mode
Setting
LED
Zoom
Mode
Setting
LITE automated lighting equipment is made in the U.S.A.
1 7 Dec emb er 2 012
M
S
ANUAL
3 x 120W RGBW LEDs
Distance
(ft)
16
32
48
64
80
16
32
48
64
80
3 x 120W RGBW LEDs
Distance
(m)
5
10
15
20
25
5
10
15
20
25
Field Diameter
Center Beam
(ft)
Illuminance (fc)
4.3
670
8.5
167
12.8
74
17.1
42
21.4
27
22.8
49
45.7
12
68.5
5
91.4
3
114.2
2
Field Diameter
Center Beam
(m)
Illuminance (lux)
1.3
6859
2.7
1715
4.0
762
5.3
429
6.7
274
7.1
500
14.3
125
21.4
56
28.6
31
35.7
20
02 .9 703 .00 01 A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLX3 and is the answer not in the manual?

Table of Contents