S5-95F
IP 262 Closed-Loop Control Module (continued)
Technical Specifications
Controller
Total cycle time
(equals scan time)
Resolution of the
open-loop controller
Analog Inputs
Number of inputs
Additional input for
reference temperature
Galvanic isolation
Permissible voltage difference
Between inputs
Between inputs and
central ground point
Digital representation
of the input signal
Current input
Input signal range
Input resistance
mV Input (for thermocouple)
Input signal range
Cable impedance
Resistance thermometer
Start
End
Permissible cable impedance
Binary Inputs
Number of inputs
Galvanic isolation
Signal state "0"
Signal state "1"
Input resistance
Analog Outputs of Constant
Controller (6ES5 262-8MA12)
Number of outputs
Galvanic isolation
Output signal range
Maximum permissible load
No load voltage
EWA 4NEB 812 6210-02
100 to 200 ms
5 ms at 50 Hz
4.2 ms at 60 Hz
4 (suited for current,
thermocouple, or
resistance thermo-
meter), voltage with
external switching
1 (resistance
thermometer)
no
- 1 V to +1 V
- 1 V to +1 V
11 bits+sign
0 to 20 mA or
4 to 20 mA
24.3 ±0.1%
0 to 50 mV or
- 8.9 to 41.1 mV
(type J, K, L, S)
30 per wire
18.49
219.12
30 per wire
4
no
- 30 to+4.5 V
or open
+13 to +30 V
(signal state
invertible)
approx. 4 k
3
no
0 to 20 mA or
4 to 20 mA
600
(L+) - 2 V
Binary Outputs of the Open-Loop
Controller (6ES5 262-8MB12)
Number of outputs
Galvanic isolation
Signal state "0"
Signal state "1"
Maximum load current
Wiring method
Programmer (PG)
Operator panel (OP)
SINEC-L1 network connection
Connectable are
Analog and binary inputs
Analog and binary outputs
General data
Input voltage
Rated value
Permissible range
Permissible range with
the PG 605/OP 393
Current consumption
Internal (from
the CPU; 9 V)
approx. 20 mA
External (for 24 V;
without load)
approx. 180 mA
External (for 24 V;
without load;
with PG 605 / OP 393)
approx. 340 mA
Ambient temperature
EMC Characteristics for Use in S5-95F
Electrostatic discharge
to IEC 801-2
tested with
Electromagnetic fields
to IEC 801-3
tested with
Fast transient burst
to IEC 801-4
tested with
Module Spectrum
(6ES5 262-8MA12)
(6ES5 262-8MB12)
8
no
<1.5 V
(L+) - 3.8 V
100 mA short-circuit
proof
front side via
15-pin sub D
connector
PG 605, PG 710,
PG 730, PG 750,
PG 770, OP 393,
OP 395
front side via
25-pin sub D
connector
via terminal block of
the bus unit
24 V DC
18 to 34 V DC
18 to 27 V DC
0° to 55°C
(32 to 131 °F)
Severity rating: none
6 kV air discharge
<2 kV contact
discharge
Severity rating 2
3 V / m
Severity rating 3
1.2 kV on supply lines
1 kV on signal lines
A-35