STEP 5 Operations
Load Operation
During loading, information is copied from a memory area, e.g., from the PII, into ACCU 1.
The previous contents of ACCU 1 are shifted to ACCU 2.
The original contents of ACCU 2 are lost.
Example:
Two consecutive bytes (IB7 and IB8) are loaded from the PII into the accumulator.
Loading does not change the PII (see Figure 8-2).
Lost
information
Byte d
Byte c
Byte b
Byte a
Transfer Operation
During transfer, information from ACCU 1 is copied into the addressed memory area, e.g., into the
PIQ.
This transfer does not affect the contents of ACCU 1.
Example:
Figure 8-3 shows how byte a, the low byte in ACCU 1, is transferred to QB5.
ACCU 2
Byte d
Byte c
Byte d
Byte c
8-12
ACCU 2
Byte d
Byte c
Byte b
Byte a
0
IB 7
Figure 8-2. Execution of the Load Operation
ACCU 1
Byte b
Byte a
Byte b
Byte a
Figure 8-3. Transferring a Byte
ACCU 1
Byte b
Byte a
0
IB 7
0
IB 8
Information
in the PIQ
T QB 5
Byte a
S5-95F
Information
from the PII
L IB 7
IB 7
L IB 8
IB 8
Lost
information
Previous value
of QB5
EWA 4NEB 812 6210-02