6.3.6 SystemTimeout

This command queries or sets the system timeout value.
If the SystemTimeout is greater than zero, and the PDS-8x1 does not receive any packets from any
client for longer than the SystemTimeout period, the PDS-8x1 will reboot itself.
Effect: Immediate
Command
Arguments
SystemTimeout
SystemTimeout = nnnnn
Figure 6-3.6:
The following is an example of a SystemTimeout configuration.
Description
Queries the SystemTimeout settings.
Sets the SystemTimeout. (Unit : ms)
Default factory setting is 300000 ms (= 300 seconds = 5
minutes )
Min. value is 30000 ms (= 30 seconds)