ICPDAS PDS-811 User Manual page 63

Pds-8x1 series; programmable device server with i/o expansion slot
Table of Contents

Advertisement

Programmable Device Server with I/O Expansion Slot(s)
The following are examples of pair-connection tests:
Pair-connection Settings:
Model
COM
Port
PDS-8x1 #1
COM1
(Client Mode)
PDS-8x1 #2
COM1
(Server Mode)
Note:
The Baud Rate and Data Format settings of the client and server (PDS-8x1 #1 and #2) depend
on the COM ports of the PC (or the connected device).
Follow the procedure described below:
Step 1: Connecting to a network, PC and Power
1. Confirm that the PDS-8x1 controllers are functioning correctly. Refer to
PDS-8x1 controller
for more details.
2. Connect COM1 of the PC to COM1 of the PDS-8x1 #1, and then connect COM2 of the PC to
COM1 of the PDS-8x1 #2. For detailed RS-232 wiring information, refer to
Notes for RS-232/485/422
3. Supply +24 V
(+10 ~ +30 V
DC
※ Refer to
Figure 5-3.1
Port Settings
(default)
Baud
Data
Rate
Format
9600
8N1
9600
8N1
Interfaces".
) power to the PDS-8x1 controller.
DC
for an illustration of how to perform the above steps.
PDS-8x1 Series User Manual, Version 1.1.2, Apr. 2015
Pair-connection Settings
Remote
Server IP
IP Address of PDS-8x1 #2
-
Remote TCP Port
(default)
10001
-
Chapter 3 Setting up the
Section 2.7 "Wiring
- 63 -