ICPDAS PDS-811 User Manual page 43

Pds-8x1 series; programmable device server with i/o expansion slot
Table of Contents

Advertisement

Programmable Device Server with I/O Expansion Slot(s)
The following is an overview of the parameters contained in the IP Filter Setup Page section:
Item
Set IP1 only
Set IP1 + IP2
Set IP1 + Mask
Set a single IP address, the IP address entered in the "IP1" and
"IP2/MASK" text fields will be the same, as the image below shows.
Only clients who's IP address is included in the filter table are able to
connect to the PDS-8x1 controller.
Set a range of IP address as a starting and ending point. The initial IP
address must be entered in the "IP1" text field and final IP address
must be entered in the "IP2/MASK" text field, as the image below
shows.
This allows clients who's IP address is included in the range of
10.0.9.5 to 10.0.9.55 are able to connect to the PDS-8x1 controller.
Set the IP Filter (Available IP) range, the IP address must be entered in
the "IP1" text field and Mask address must be entered in the
"IP2/MASK" text field, as the image below shows.
This allows clients who's IP address is included in the range of
10.0.9.0 to 10.0.9.255 are able to connect to the PDS-8x1 controller.
Note that how to get the IP address range 10.0.9.0 to 10.0.9.255?
It's calculated as follows:
Formula:
(IP1 & MASK)
(10.0.9.5 & 255.255.255.0)
(10.0.9.0)
10.0.9.0
PDS-8x1 Series User Manual, Version 1.1.2, Apr. 2015
Description
to
(IP1 & Mask) + (~MASK)
to
(10.0.9.5 & 255.255.255.0) + (0.0.0.255)
to
(10.0.9.0) + (0.0.0.255)
to
10.0.9.255
- 43 -