4. Click in the Default Gateway input fields and fill out the 4 octets. Set the Default-Gateway to the IP-Address of the router (MUST
be on the local subnet!).
Note:
This must NOT be 0.0.0.0.
If there is no router on the local subnet then just set this field to any IP-Address on the subnet.
5. Click in the DNS Servers input field and fill out the preferred DNS servers (maximum 5) in a comma separated list.
6. Click Save changes to apply the settings.
Do not use IP address 192.168.2.x for a Subnet mask 255.255.255.0 and IP address 192.168.x.x for a Subnet
mask 255.255.0.0
Use a proxy server
This setting is important for the auto-update feature of the Base Unit, which require internet access.
1. Check the check box next to Use a proxy server.
Image 6-24
Proxy settings
The proxy settings become available.
2. Enter the proxy server address. Enter the IP address or hostname.
Some proxy servers need a port number, user name and password, for others is this optional.
3. Optionally, enter the used server port.
4. Optionally, enter the user name.
5. Optionally, enter the password.
6. Click Save changes to apply the settings.
For the moment, only the primary network connector can be used for API, Management Suite and Network
Integration.

6.13 Network integration, activation

Introduction
"ClickShare Network Integration" aims at deploying ClickShare in larger organizations without interfering with the existing wireless
network infrastructure. In a default stand-alone setup, the ClickShare Base Unit creates its own wireless access point (AP) which
the ClickShare Buttons use to connect. These so-called "rogue" APs can become a nuisance in larger installations. Next to that,
meeting participants who are sharing content from mobile devices have to switch networks to connect with the ClickShare Base Unit.
This is where ClickShare Network Integration comes in. Once fully configured and enabled, the built-in AP of the Base Unit is
disabled. The Button or the mobile devices can then connect to a wireless access point that is part of the corporate network. At this
point, the Base Unit needs to be connected to the corporate network via the wired Ethernet interface so that the Buttons and mobile
devices can share their content on the Base Unit.
R5900049 CLICKSHARE CSE-800 19/03/2018