6.7 Connectors

Given voltage and current data are the lowest values allowed by UL and CE. 
Connector
Hybrid IN, X1
Hybrid OUT, X2
Digital I/O, X3
Motor, X4
Feedback X5
STO/Fieldbus, X6 Connector (female),
* Rated voltage with pollution level 2, use Kollmorgen cables only.

6.8 Cable Requirements

For information on the chemical, mechanical, and electrical characteristics of the cables
please refer to the accessories manual or contact customer support.
Use Kollmorgen hybrid, motor, and feedback cables only. You will loss system warranty, if
you use hybrid, motor or feedback cables from a manufacturer other than Kollmorgen.
Cable from
AKD-C X20/X21
AKD-N X2
AKD-N X3
AKD-N-DB/DS/DF X4 CCJNA1-015
AKD-N-DS/DF X4
AKD-N-DS/DF X4
AKD-N-DS/DF X5
AKD-N-DS/DF X5
AKD-N-DS/DF X5
AKD-N-DS/DF X5
AKD-N-DF X6
AKD-N-DS X6
1)
Followed by length coding. Contact your Kollmorgen sales representative.
2)
Example, similar cables are available from other distributors.
AKD-N Installation | 6   Technical description and data
Type
Max. Cross Section
Hybrid Connector
4 x 0.34mm², 22 awg
(male), 7 poles
3 x 2.5 mm², 14 awg
Hybrid Connector
4 x 0.34mm², 22 awg
(female), 7 poles
3 x 2.5 mm², 14 awg
Connector (female),
8 x 0.34 mm², 22 awg
8 poles
Connector (female),
4 x 2.5 mm², 14 awg
8 poles
4 x 1.0 mm², 18 awg
Connector (male),
17 x 0.75 mm², 20 awg
17 poles
4 x 0.34 mm², 22 awg
4 poles
Cable type
Cable to
1)
CCNCN1-025
AKD-N X1, hybrid
1)
CCNNN1-025
AKD-N X1, hybrid
Phoenix SAC-
Digital I/O
2)
8P-M12MS
1)
Motor Power with brake and
Hiperface DSL feedback,
hybrid
1)
CM0NA1-015
Motor Power without brake
1)
CM1NA1-015
Motor Power with brake
1)
CFSNA1-002
Motor Feedback SFD
1)
CFCNA1-002
Motor Feedback Comcoder
1)
CFENA1-002
Motor Feedback EnDat/BiSS
1)
CFHNA1-002
Motor Feedback Hiperface
Phoenix NBC-
Tertiary Fieldbus
2)
MSD/5,0-93E
Phoenix SAC-
Single Drive STO switch
2)
4P-M12MS
Current
Voltage*
0.5 A
30 V
18 A
850 V
0.5 A
30 V
18 A
850 V
2 A
30 V
15 A
630 V
10 A
30 V
3.6 A
63 V
1 A
50 V
Cross
section
3 x 2.5 mm²
4 x 0.25 mm²
3 x 2.5 mm²
4 x 0.25 mm²
8 x 0.25 mm²
4 x 1.5 mm²
2 x 0.75 mm²
2 x 0.34 mm²
4 x 1.5 mm²
4 x 1.5 mm²
2 x 0.75 mm²
4 x 2 x 0.25 mm²
7 x 2 x 0.25 mm²
7 x 2 x 0.25 mm²
7 x 2 x 0.25 mm²
2 x 2 x 0.14 mm²
4 x 0.34 mm²