3-1-2. Main circuit terminals

DS2-20P2-AS/AS6, DS2-20P4-AS/AS6, DS2-20P7-AS/AS6
Terminal
L1/L2/L3
P+、PB
U、V、W Motor terminals
DS2-21P5-AS/AS6/AS2, DS2-22P3-AS/AS6, DS2-41P5-AS/AS6
Terminal
R
R/S/T
.
S
R/S/T
T
U
V
U、V、W Motor terminals
W
P+
D
C
P+、D、C
Function
Power supply input of
main circuit
Ground
Regenerative resistor
Ground
Function
Power supply input of
main circuit
Power supply input of
main circuit
Vacant
Internal
regenerative
resistor
External
regenerative
resistor
Ground
Explanation
Single or 3 phase AC 200~240V, 50/60Hz
Connect to ground terminal of motor then
connect to the ground
Connect regenerative resistor between P+
and PB
Connect the motor
Terminal
Color
U
brown
V
black
W
blue
PE
Yellow green
Connect to ground terminal of motor then
connect to the ground
Explanation
3 phase AC 200~240V, 50/60Hz
(DS2-2□P□-AS)
3 phase AC 360~400V, 50/60Hz
(DS2-4□P□-AS)
Connect the motor
Terminal
Color
U
brown
V
black
W
blue
PE
Yellow green
Short P+ and D, disconnect P+ and C,
set P0-10=0
Connect regenerative resistor between
P+ and C, disconnect P+ and D, set
P0-10=1
Connect to ground terminal of motor,
then connect to the ground
11