Xinje DS2-20P2-AS User Manual page 20

Ds2 series
Hide thumbs Also See for DS2-20P2-AS:
Table of Contents

Advertisement

DS2-43P0-AS/AS6
R
Terminal
.
R/S/T
S
T
U
.
U、V、W Motor terminals
V
W
P+、D、C
P+
D
C
P-
P+/P-
DS2-20P4-BS/BS6
Terminal
L/N
.
.
U、V、W Motor terminals
P+/PB
P+/P-
Function
Power supply input of
main circuit
Vacant
Internal
regenerative
resistor
External
regenerative
resistor
Bus terminal
Function
Power supply input of
main circuit
Vacant
External
regenerative
resistor
Bus terminal
Explanation
3 phase AC 360~400V, 50/60Hz
Connect the motor
Terminal
Color
U
brown
V
black
W
blue
PE
Yellow green
Short P+ and D, disconnect P+ and C,
set P0-10=0
Connect regenerative resistor between
P+ and C, disconnect P+ and D, set
P0-10=1
Real-time check the bus voltage, please
take attention of this terminal
Explanation
Single phase AC 200~240V, 50/60Hz
Connect the motor
Terminal
Color
U
brown
V
black
W
blue
PE
Yellow green
Connect regenerative resistor between
P+ and PB
Real-time check the bus voltage, please
take attention of this terminal