Main Circuit Wiring; Servo Driver Terminal Arrangement; Main Circuit Terminals - Xinje DS5F Series User Manual

Servo driver
Table of Contents

Advertisement

3.1 Main circuit wiring

3.1.1 Servo driver terminal arrangement

Power supply
Motor wiring
Regenerative

3.1.2 Main circuit terminals

DS5F-20P1-PTA, DS5F-20P2-PTA, DS5F-20P4-PTA, DS5F-20P7-PTA
L
Terminal
N
L/N
U
V
W
U, V, W
P+
D
P+, D, C
C
DS5F-21P5-PTA, DS5F-22P3-PTA, DS5F-22P6-PTA
R
Terminal
S
T
R/S/T
U
V
U, V, W
W
P+
D
C
P+, D, C
resistor
Function
Power supply input of
main circuit
Vacant terminal
Motor terminals
Internal
regenerative
resistor
External regenerative
resistor
Function
Power supply input of
main circuit
Vacant terminal
Motor terminals
Internal
regenerative
resistor
External regenerative
resistor
Ground terminal
RS232 port
Multifunction terminal
Encoder output
Encoder interface
Explanation
Single phase AC 200~240V, 50/60Hz
-
Connect the motor
Note: the ground wire is on the cooling
fin, please check it before power on!
Short P+ and D, disconnect P+ and C
Connect regenerative resistor between P+
and C, disconnect P+ and D, P0-25=
power value, P0-26= resistor value
Explanation
3-phase (R,S,T) AC200~240V, 50/60Hz
Single phase (R,T) AC200~240V, 50/60Hz
-
Connect the motor
Note: the ground wire is on the cooling fin,
please check it before power on!
Short P+ and D, disconnect P+ and C
Connect regenerative resistor between P+
and C, disconnect P+ and D, P0-25= power
value, P0-26= resistor value
Connect to ground terminal of motor, then
connect to the ground
31

Hide quick links:

Advertisement

Table of Contents
loading