Xinje DS2-20P2-AS User Manual page 89

Ds2 series
Hide thumbs Also See for DS2-20P2-AS:
Table of Contents

Advertisement

wire break
Speed changes too
E-015
fast (encoder
feedback error)
E-016 Overload
Power off when
E-017
running
Erase parameter
E-018
error
E-031 Motor code error
E-032 Initialization error
encoder broken,
encoder is not
connected
The encoder wiring is
error, or the encoder
has interference
Run overload for long
time
Bus voltage is too low
when running
Voltage is too low
when power on,cannot
erase the parameter
Motor code cannot
match to drive type
System chip is
damaged
re-connect the encoder after
power-off, or replace the damaged
encoder
Check the wiring of encoder, or
add shield layer for the encoder
wire
Reduce the overload running time,
change a motor with larger rated
power
Re-power on after the bus voltage
is normal
Check the power supply and
re-power on
Set the motor code in F2-00 again
Contact Xinje or an authorized
distributor