Effective value of current up to 7.0A/5.0A Dynamic select the subdivision, can up to 300 The DP-708 driver can match with all the 4/6/8 wires motors whose current is below 7.0 A Photo isolation signal input ...
DP-708/DP-5022 series stepper driver 2. Operation Guide Please read the following suggestions carefully before you install the driver. 2-1. Safety The driver is authorized to be installed and operated by the professional staff. Don’t turn on the power before connecting to the motor.
DP-708/DP-7022series subdivision driver user’s manual 3. Common Terminals POWER CHARGE STA|ESC ENTER CAUTION! 3-1. Control signal terminals 3-1-1. Description of Control signal terminals Signal Function Description Communication RS485 communication terminal Pulse control The rising edge is effective; motor moves one step at the...
DP-708/DP-5022 series stepper driver 3-1-2. Sequential chart of control signals In order to ensure the reliability of the system response, please take the following advices. The signal high voltage is 24V; low voltage is less than 0.5V. The ENA (enable) signal should turn to high-level at least 3s before DIR (direction) signal.
To keep the normal working of drive, please ensure the power supply in this range: DP-708: 20~80VDC; DP-5022: 200~240VAC. For DP-708, it is advised to use non-regulated DC power supply, and make sure the current output of power is 60% higher than setting current of driver.
Page 10
DP-708/DP-5022 series stepper driver 2-Phase Step Motor 20~80VDC Note: The motor performance depends on the connection between driver and motor. Generally, the high-speed performance of motor depends on the power supply voltage (the higher the power voltage, the higher the high-speed torque, can avoid the step missing), and the output torque depends on the setting current (the greater the setting current, the higher the output torque of motor).
DP-708/DP-7022series subdivision driver user’s manual DP-5022 3-Phase Step Motor AC200~240V Notes: Generally, the motor high-speed performance depends on the driver power voltage (the bigger the power voltage, the higher the high-speed torque, step loss is avoided effectively), motor output torque depends on the setting current (the larger the setting current, the higher the motor output torque).
DP-708/DP-5022 series stepper driver 3-3-1. Current Setting Set the current in the range of 0~0.7A/5.0A through the parameter P0-00. Set the half-current or full-current mode through the parameter P0-01. 3-3-2. Subdivision Setting The subdivision precision can be set through the parameter P0-02,for more details please refer to chapter 4-2.
DP-708/DP-7022series subdivision driver user’s manual 4-1-2.Basic state switching Display the running state, set the parameters and run the command through digital panel state switching. The basic states include running state, monitor state, auxiliary function state, parameter setting state, alarm state (visible when error). The states will change as the following chart after touching the STATUS/ESC button.
Page 14
DP-708/DP-5022 series stepper driver Table 1 driver parameters Name Unit Default Setting range Reference setting Phase-current (virtual value) 0.1A 0~70 Half-current enable 0: Half-current 1: Full-current Pulse number per circle 1600 200~65535 Modbus station NO. 1~255 Parameters of serial port...
DP-708/DP-7022series subdivision driver user’s manual press ENTER key and hold to confirm. 3. At this time, the panel displays the value in parameter P0-02, and the “0” at the lowest bit is blinking, press ENTER key to left shift the blinking bit. Press INC, DEC or ENTER key to modify the value to 3200, and press and hold ENTER key to confirm.
DP-708/DP-5022 series stepper driver External communication monitoring F3-00 Forced enable F4-00 Check System Information 4-4-1. Press the STATUS/ESC key to select the auxiliary function mode. Set the group No. to 0 to check system information. Press INC or DEC key to select different No., and press and hold ENTER key to check current information.
DP-708/DP-7022series subdivision driver user’s manual 4-4-3.Reset Parameters to Default The following steps show how to reset parameters to default values. 1. Press STATUS/ESC key to select Auxiliary Function. 2. Press INC or DEC key to set group No. to 2, and press ENTER key to confirm.
Page 18
DP-708/DP-5022 series stepper driver temperature is higher ambient temperature. than normal. Driver output to Over Change the damaged motor and ● E-006 motor error or motor Current check motor wiring error System System IC is Contact Xinje or an authorized ●...
DP-708/DP-7022series subdivision driver user’s manual 5. Dimension installation and wiring Unit: mm 5-1. Dimension 5-2. Installation Install the driver in the well-ventilated and protected electric cabinet, check the fan regularly. To ensure the driver heat dissipation is well, keep at least 10cm space when installing.
Page 20
DP-708/DP-5022 series stepper driver DP-5022 please separate the power cables (power supply cable and motor phase cable) Note: and the weak electricity cable in order to avoid interference.
DP-708/DP-7022series subdivision driver user’s manual 6. Malfunction Diagnoses and Solution Malfunction Causation Solution Something wrong with the power The power light doesn’t Check the power supply supply work The power voltage is too low Increase the power voltage Setting current is too low...
DP-708/DP-5022 series stepper driver 7. Motor Selection The DP-708 series driver matches with 4/6/8 wires 2-phase hybrid stepper motor. Please select the suitable motor and driver. The DP-5022 series driver matches with 3/6 wires 3-phase hybrid stepper motor. Please select the suitable motor and driver.
Page 23